Acceptance and Commissioning of a Treatment Planning System Based on Monte Carlo Calculations

Abstract: The Monaco Treatment Planning System (TPS), based on a virtual energy fluence model of the photon beam head components of the linac and a dose computation engine made with Monte Carlo (MC) algorithm X-Ray Voxel MC (XVMC), has been tested before being put into clinical use. An Elekta Synergy with 6 MV was characterized using routine equipment.After the machine's model was installed, a set of functionality, geometric, dosimetric and data transfer tests were performed. The dosimetric tests included dose calculati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…In the past, the experimental validation study of Monaco was limited to the XVMC algorithm 15 , 16 . Although there exists an evaluation study of a standalone version of the GPUMCD algorithm for IMRT optimization, (17) no work has been done, to our knowledge, on the experimental evaluation of the GPUMCD algorithm implemented in the Monaco TPS.…”
Section: Introductionmentioning
confidence: 99%
“…In the past, the experimental validation study of Monaco was limited to the XVMC algorithm 15 , 16 . Although there exists an evaluation study of a standalone version of the GPUMCD algorithm for IMRT optimization, (17) no work has been done, to our knowledge, on the experimental evaluation of the GPUMCD algorithm implemented in the Monaco TPS.…”
Section: Introductionmentioning
confidence: 99%
“…Our dosimetric results confirm that the XVMC algorithm implemented in iPlan can accurately calculate the dose under conditions of low density and small fields (IMRT) as reported by other studies. [23][24][25] It is known that the PB algorithm fails to calculate the correct dose when the tissue density varies significantly from the density of water and thus the range of lateral electrons is increased. This effect is intensified under deep inspiration breath hold conditions, where the lung density can be as low 11 as 0.16 g/cm 3 .…”
Section: Discussionmentioning
confidence: 99%
“…– 17 It is widely accepted that Monte Carlo (MC) algorithms model electron transport in different media and therefore perform better dose calculation in a heterogeneous medium than that of the less complex algorithms. MC algorithm also affords more elegant ways to deal with the complex scatter patterns of treatment machines and beam modifying equipment 18 . CMS Monaco (Elekta CMS, Sunnyvale, CA, USA) is a commercially available planning system which uses an X-ray voxel Monte Carlo (XVMC) algorithm 19 .…”
Section: Introductionmentioning
confidence: 99%
“…MC algorithm also affords more elegant ways to deal with the complex scatter patterns of treatment machines and beam modifying equipment. 18 CMS Monaco (Elekta CMS, Sunnyvale, CA, USA) is a commercially available planning system which uses an X-ray voxel Monte Carlo (XVMC) algorithm. 19 Not many studies on the validation of Monaco XVMC algorithm in an heterogeneous medium have been published concerning small fields.…”
Section: Introductionmentioning
confidence: 99%