2018
DOI: 10.1115/1.4040923
|View full text |Cite
|
Sign up to set email alerts
|

Accelerated Vibration Reliability Testing of Electronic Assemblies Using Sine Dwell With Resonance Tracking

Abstract: In this work, a sinusoidal vibration test method with resonance tracking is employed for reliability testing of circuit assemblies. The system continuously monitors for changes in the resonant frequency of the circuit board and adjusts the excitation frequency to match the resonant frequency. The test setup includes an electrodynamic shaker with a real-time vibration control, resistance monitoring for identifying electrical failures of interconnects, and vibration logging for monitoring changes in the dynamic … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
22
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(22 citation statements)
references
References 15 publications
0
22
0
Order By: Relevance
“…For solder failure detection, an Analysis Tech 256STD (Analysis Tech, Wakefield, Massachusetts, USA) standard event detector was combined with an Agilent 34980 A resistance logger to monitor solder resistance changes using Benchlink Data Logger Software. For further information on this test, readers are strongly encouraged to refer to reference (Su et al , 2018). The schematic of this test setup is shown in Figure 3.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For solder failure detection, an Analysis Tech 256STD (Analysis Tech, Wakefield, Massachusetts, USA) standard event detector was combined with an Agilent 34980 A resistance logger to monitor solder resistance changes using Benchlink Data Logger Software. For further information on this test, readers are strongly encouraged to refer to reference (Su et al , 2018). The schematic of this test setup is shown in Figure 3.…”
Section: Methodsmentioning
confidence: 99%
“…For vibration reliability assessment, several experimental (Su et al , 2018; Su et al , 2014; Yu et al , 2011; Gharaibeh, 2018), numerical studies via finite element analysis (FEA) simulations (Gharaibeh, 2018; Xia et al , 2017; Xia et al , 2017) and analytical methods (Gharaibeh et al , 2016; Gharaibeh, 2018; Gharaibeh, 2018; Gharaibeh et al , 2018; Gharaibeh et al , 2017; Gharaibeh and Pitarresi, 2019) have been developed. Also, the reliability of electronic assemblies under thermal cycling has been widely discussed (Joshi et al , 2012; Obaidat et al , 2016; Chang et al , 2006; Barker et al , 1990; Barker et al , 1991; Barker et al , 1991).…”
Section: Introductionmentioning
confidence: 99%
“…The new driving frequency is the resonant frequency of the system which has drifted due to some change in the material of the assembly. For further information on this test, readers are strongly encouraged to refer to reference (Su et al , 2018).…”
Section: Methodsmentioning
confidence: 99%
“…Electronics nowadays come in smaller, thinner and lighter specifications, and they can be found in different applications, for example, computers, laptops and handheld devices. Therefore, extensive experimental (Chen et al , 2008; Su et al , 2018; Su et al , 2014), numerical (Gharaibeh, 2018a; Xia et al , 2017a; Xia et al , 2017b; Gharaibeh, 2018c) and analytical (Obaidat et al , 2016; Gharaibeh, 2018b; Gharaibeh et al , 2017; Gharaibeh et al , 2018) methodologies were developed to study and evaluate the reliability of critical components.…”
Section: Introductionmentioning
confidence: 99%
“…According to the literature, an effective method to track the resonant frequency is the auto-phase SRTD test using the phase difference between the signals from 2 sensors. [21][22][23] The reference accelerometer is attached to the fixer of the cantilever beam, whereas the response accelerometer is attached to the end of the beam. A sine sweep test is conducted first to obtain the resonant frequency, at which the response accelerometer reaches its peak.…”
Section: Auto -Phase Srtd Vibration Experimentsmentioning
confidence: 99%