In this paper, a minimax design of damped dynamic vibration absorber for a damped primary system is investigated to minimize the vibration magnitude peaks. Moreover, to reduce the sensitivity of the primary system response to variations of the forcing frequency for a twodegree-of-freedom system, the primary system should have two equal resonance magnitude peaks. To meet this requirement, a set of simplified constraint equations including distribution characteristics of the resonant frequencies of the primary system is established for the minimax objective function. The modified constraint equations have less unknown variables than those by other authors, which not only simplifies the computation but also improves the accuracy of the optimal values. The advantage of the proposed method is illustrated through numerical simulations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.