2013
DOI: 10.1039/c3ja50052g
|View full text |Cite
|
Sign up to set email alerts
|

Accelerated evaporation of microdroplets at ambient conditions for the on-line analysis of nanoparticles by inductively-coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
46
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 39 publications
(47 citation statements)
references
References 29 publications
(30 reference statements)
0
46
0
Order By: Relevance
“…Therefore, a desolvation system is often used prior to introduction of the droplets into the ICP. One example uses He in a long tube to allow droplets to evaporate at a much higher rate than in Ar without the need for heating [36,75]. Monodisperse droplet generator designs include a capillary surrounded by a piezoelectric tube that ejects a droplet when a voltage pulse is applied, a microfluidics based droplet dispenser [76], and thermal ink jet printer-like designs [77].…”
Section: Sample Introductionmentioning
confidence: 99%
“…Therefore, a desolvation system is often used prior to introduction of the droplets into the ICP. One example uses He in a long tube to allow droplets to evaporate at a much higher rate than in Ar without the need for heating [36,75]. Monodisperse droplet generator designs include a capillary surrounded by a piezoelectric tube that ejects a droplet when a voltage pulse is applied, a microfluidics based droplet dispenser [76], and thermal ink jet printer-like designs [77].…”
Section: Sample Introductionmentioning
confidence: 99%
“…In these systems, the sample solution is injected into the plasma as a single droplet instead of being nebulized. 13,14 In our research group, microdroplet injection was also developed to introduce single cells into an ICP. [15][16][17] In this system, the sample introduction efficiency equals 100%; in principle and the sample does not tend to diffuse in the plasma.…”
mentioning
confidence: 99%
“…For optimum desolvation and transport of the microdroplets, He was passed both through the dispenser head (sheath gas) and the rst gas inlet position (carrier gas), as it has been reported in the past to effectively dry droplets in short time even at room temperature. 28,43 Ar was passed through the Tjunction of the MDI near the end of the vertical transfer tube (make-up gas) for nal transfer of the droplets towards the horizontal torch injector.…”
Section: Methodsmentioning
confidence: 99%