1999
DOI: 10.1016/s0301-5629(98)00142-2
|View full text |Cite
|
Sign up to set email alerts
|

A validation study on the intraobserver and interobserver reproducibility of renal artery duplex ultrasound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
20
0
1

Year Published

2001
2001
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(24 citation statements)
references
References 18 publications
3
20
0
1
Order By: Relevance
“…These results agree with the findings of Baumgartner and associates, that while examining the reproducibility of this method in healthy individuals, demonstrated that the RAR presented an average of 0.85 ± 0.41, suggesting that values lower than 3.5 could be associated with significant renal artery stenosis, without losing the specificity of the method 20 . Although a RAR of 3.5 had produced an elevated specificity (93%) it provoked considerable loss in sensitivity (79%).…”
Section: Discussionsupporting
confidence: 92%
See 1 more Smart Citation
“…These results agree with the findings of Baumgartner and associates, that while examining the reproducibility of this method in healthy individuals, demonstrated that the RAR presented an average of 0.85 ± 0.41, suggesting that values lower than 3.5 could be associated with significant renal artery stenosis, without losing the specificity of the method 20 . Although a RAR of 3.5 had produced an elevated specificity (93%) it provoked considerable loss in sensitivity (79%).…”
Section: Discussionsupporting
confidence: 92%
“…Parameters analyzed: PSV and RAR -The technical success rate for detecting the renal arteries was 100%, concurrent with the success rates of recent studies (95-100%) 20,21 . The mean values ± SD of renal artery PSV presented a significant statistical difference (p < 0.005) between the groups with RAS 0-59% and RAS 60-99% (see table 3) in agreement with the results obtained in various publications 22,23,24 .…”
Section: Discussionsupporting
confidence: 64%
“…Als indirekte Stenosekriterien verwendet werden der Resistance-Index nach Pourcelot (RI), der Pulsatilitäts-index und die Akzelerationszeit intrarenal gemessen bzw. die Analyse der intrarenal abgeleiteten pw-Dopplerkurve [1,3,4,11,21,22].…”
Section: Introductionunclassified
“…7 But, still an error range of up to 10% exists and, hence, TCCD measurements are only trustable up to this accuracy. 4 Conversion of quantities With die TCCD device flow velocities instead of volumetric flow as required for the comparison with the flow quantification algorithm were measured. Hence, the extracted projected centerline velocities from TCCD were used together with the information of the vessel radius to compute the volumetric blood flow based on the Womersley assumption of velocity distribution over the vessel cross section.…”
Section: Discussionmentioning
confidence: 99%