2016
DOI: 10.1039/c5ay02746b
|View full text |Cite
|
Sign up to set email alerts
|

A validated stability-indicating HPLC-DAD method for simultaneous determination of econazole nitrate, triamcinolone acetonide, benzoic acid and butylated hydroxyanisole in cream dosage form

Abstract: A comprehensive stability-indicating HPLC-DAD method for simultaneous determination of econazole nitrate (EN), triamcinolone acetonide (TA), benzoic acid (BA) and butylated hydroxyanisole (BHA).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 37 publications
0
7
0
Order By: Relevance
“…Benzoic acid and butylated hydroxyanisole were found in the dosage form and showed marked stability (28). One HPLC method was reported for the stability study of TMC and ECZ along with benzoic acid and butylated hydroxyanisole under different stress conditions using gradient elution and changing the wavelength of analysis (23).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Benzoic acid and butylated hydroxyanisole were found in the dosage form and showed marked stability (28). One HPLC method was reported for the stability study of TMC and ECZ along with benzoic acid and butylated hydroxyanisole under different stress conditions using gradient elution and changing the wavelength of analysis (23).…”
Section: Resultsmentioning
confidence: 99%
“…ECZ and estradiol were determined in human plasma by near-IR spectrometry (21). Two HPLC methods were found for the determination of TMC and ECZ in binary mixtures (22) and in the presence of their degradation products (23) without any isolation or identification of the degradation products. However, no method was found for the determination of the studied compounds in the presence of TMC impurities.…”
mentioning
confidence: 99%
“…The tested compounds included some commonly used in antimicrobial veterinary products. This approach to test the specificity of an HPLC method was put into practice in several previous studies . About 22 compounds were found completely separated from the drugs under analysis.…”
Section: Resultsmentioning
confidence: 99%
“…If the purity angle is less than the calculated threshold angle, the peak is spectrally homogeneous. If the purity angle is greater than the threshold, there is something within the peak that cannot be explained by noise, and consequently the peak is considered impure or not spectrally homogeneous [30,31]. The obtained purity angles were below the threshold limits as shown in the Supporting Information Figs.…”
Section: Assay Of Tablets Dosage Formsmentioning