A Validated Low-cost Training Model for Suprapubic Catheter Insertion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 4 publications
(3 reference statements)
0
7
0
Order By: Relevance
“…On the analysis of the six articles found, it was verified that three of them are related to the insertion of suprapubic catheters models [9][10][11] , one article described the use of a computer software associated to sensors in the mannequin to evaluate precisely the quality of the procedure 12 ; other article proposed a model with cadavers and the last one a porcine model 13 (Table 1). Regarding the publication dates of the papers, the oldest one was published in the year 2000 and the most recent in 2015.…”
Section: Resultsmentioning
confidence: 98%
See 2 more Smart Citations
“…On the analysis of the six articles found, it was verified that three of them are related to the insertion of suprapubic catheters models [9][10][11] , one article described the use of a computer software associated to sensors in the mannequin to evaluate precisely the quality of the procedure 12 ; other article proposed a model with cadavers and the last one a porcine model 13 (Table 1). Regarding the publication dates of the papers, the oldest one was published in the year 2000 and the most recent in 2015.…”
Section: Resultsmentioning
confidence: 98%
“…It is important to point out that the three models were published at the same journal (Urology), however in different years: the Singal et al 9 model is the most recent one and was published in January 2015; the Hossack et al 10 model was published in October 2013 and the oldest model, from Shergill et al 11 was published in July 2008.…”
Section: Suprapubic Cathetersmentioning
confidence: 99%
See 1 more Smart Citation
“…Construct validity was not assessed. A similar but arguably more complicated model was developed by Singal et al [ 10 ] from moulded urethrane and resin foam and a silicone moulded bladder. The model was assessed by 6 experienced urologists, who gave the model high scores for its visual and sensory representation of skills such as trocar insertion.…”
Section: Resultsmentioning
confidence: 99%
“…In comparison to these traditional methods, our model again eliminated the step of catheter placement after removing the puncture needle core, by placing the catheter along the puncture needle in advance. Both experienced practitioners and trainees expressed satisfaction with using an anatomically correct model developed by Singal et al 11. The main features of that model were its low cost and easy reproducibility, with only bladder, skin, and fat layers needing periodic replacement.…”
Section: Discussionmentioning