2004
DOI: 10.1016/j.jpba.2004.08.014
|View full text |Cite
|
Sign up to set email alerts
|

A validated cold vapour-AAS method for determining mercury in human red blood cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
12
0
1

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 14 publications
(18 reference statements)
2
12
0
1
Order By: Relevance
“…The recovery for mercury was between 89-113%. Good recoveries of spiked samples demonstrate the accuracy of the methods used (Ertas & Tezel, 2004). Detection limit, defined as the mercury concentration corresponding to three times the standard deviation of ten reagent blanks (Ertas & Tezel, 2004) was 0.13 ng g À1 .…”
Section: Determination Of Recovery and Detection Limitmentioning
confidence: 81%
“…The recovery for mercury was between 89-113%. Good recoveries of spiked samples demonstrate the accuracy of the methods used (Ertas & Tezel, 2004). Detection limit, defined as the mercury concentration corresponding to three times the standard deviation of ten reagent blanks (Ertas & Tezel, 2004) was 0.13 ng g À1 .…”
Section: Determination Of Recovery and Detection Limitmentioning
confidence: 81%
“…Precision of the analytical method for analysis Cd and Pb (AAS-flame) and Hg (using mercury analyzer) was checked in order to show the reproducibility of responses. This parameter takes into account only the error coming from the operating system and not the error attributable to sample handling and preparation (Ertasa and Tezel, 2005).…”
Section: Resultsmentioning
confidence: 99%
“…To ensure the accuracy of the analytical method, the recovery studies were carried out by adding a known quantity of Cd, Pb and Hg into samples by the proposed method. To check the accuracy of analytical method, the recovery studies were performed in order to confirm the losses of Cd, Pb and Hg or contamination during sample preparation and matrix interferences during the measurement step (Ertasa and Tezel, 2005). According to ICH (1994) for the determination of the recoveries, the spiking technique was used, i.e., the known concentration of standard solutions of Cd, Pb and Hg were added to Capsicum annum L. and the resulting spiked samples were measured, calculated and compared to the known values of standard solutions of Cd, Pb and Hg added.…”
Section: Accuracymentioning
confidence: 99%
“…1,2,3 This kind of information can be obtained through the analysis of blood, as blood is the medium for the transport of essential and toxic trace elements. 1 The elemental determination in blood samples has been carried out through techniques such as atomic absorption spectrometry, 4,5,6,7,8 total reflection X-ray fluorescence (TXRF), 5,9 or hydride generation atomic fluorescence spectrometry (HG-AFS) 10 . However, due to the increasing demand in the number of elements to be determined in blood, alternative analytical methods are needed.…”
mentioning
confidence: 99%