2021
DOI: 10.3390/mi12080971
|View full text |Cite
|
Sign up to set email alerts
|

A Vacuum-Powered Artificial Muscle Designed for Infant Rehabilitation

Abstract: The majority of soft pneumatic actuators for rehabilitation exercises have been designed for adult users. Specifically, there is a paucity of soft rehabilitative devices designed for infants with upper and lower limb motor disabilities. We present a low-profile vacuum-powered artificial muscle (LP-VPAM) with dimensions suitable for infants. The actuator produced a maximum force of 26 N at vacuum pressures of −40 kPa. When implemented in an experimental model of an infant leg in an antagonistic-agonist configur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(18 citation statements)
references
References 52 publications
1
15
0
Order By: Relevance
“…Measurement of displacement of the piston rods of the actuators (Fig. 1) was performed using a potentiometric position transducer (10,11). The measurements of the experimental study were collected and archived via USB 231.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Measurement of displacement of the piston rods of the actuators (Fig. 1) was performed using a potentiometric position transducer (10,11). The measurements of the experimental study were collected and archived via USB 231.…”
Section: Methodsmentioning
confidence: 99%
“…These units are electrically controlled by power modules (15,16). Near the piston rods of the pneumatic cylinders, there are potentiometric position transducers (10,11), which are mechanically coupled to the piston rods of the cylinders (1, 2).…”
Section: Construction Of the Control Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…The level of CCM depends on several parameters: it is proportional to the speed [70,71], it is variable for the degree of inertia [72], to the muscle group under consideration [73] and maybe partially dependent on sex and age [74][75][76]. Other factors can also be taken into account to explain these variations [25,53,[77][78][79] in the literature, but it is always calculated as a ratio between agonist and antagonist muscles and as a function of the walking sequence (double support, unipodal phase, etc.). From a scientific point of view, TVC has been defined in different ways to facilitate its interpretation.…”
Section: Movementmentioning
confidence: 99%