2011
DOI: 10.1007/s00706-010-0438-6
|View full text |Cite
|
Sign up to set email alerts
|

A tutorial and mini-review of the ICP-MS technique for determinations of transition metal ion and main group element concentration in the neurodegenerative and brain sciences

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 75 publications
0
17
0
Order By: Relevance
“…Since the procedure involved elution of protein from the magnetic bead-antibody construct by citric acid, it was feasible to directly perform analysis of the protein fraction by inductively coupled plasma mass spectrometry (ICP-MS), which is a method for elemental analysis of liquid samples [20]. The detection of metals bound to proteins is straightforward with ICP-MS since buffers and the polypeptide chemistry do not contain metal ions [21]; in case of CisPt, the Pt element is detected and no conclusion regarding its ligation can be drawn.…”
Section: Figurementioning
confidence: 99%
“…Since the procedure involved elution of protein from the magnetic bead-antibody construct by citric acid, it was feasible to directly perform analysis of the protein fraction by inductively coupled plasma mass spectrometry (ICP-MS), which is a method for elemental analysis of liquid samples [20]. The detection of metals bound to proteins is straightforward with ICP-MS since buffers and the polypeptide chemistry do not contain metal ions [21]; in case of CisPt, the Pt element is detected and no conclusion regarding its ligation can be drawn.…”
Section: Figurementioning
confidence: 99%
“…In this study, we provide re-determined values of the molar absorption coefficients and stability constants that are valid for various experimental conditions. [50]. All of the pH buffers used in this study were treated with Chelex-100 resin to eliminate trace metal ion contamination [51][52][53].…”
Section: Introductionmentioning
confidence: 99%
“…Taking into account the literature data [27,28], an ICP-MS method and inductively coupled plasma optical emission spectrometry (ICP-OES) can be distinguished among other analytical techniques as a powerful tool in multielemental analysis in a wide range of concentrations, with high sensitivity, short time of analysis, and low limits of quantitation. Applications of ICP-MS and ICP-OES have been reported for the wide range of biological and clinical samples, both fluids (blood [29], amniotic fluid [30], and cerebrospinal fluid [31]) and solid tissues [31][32][33][34][35][36]. Complex matrices of clinical samples are often a source of interferences caused by monoatomic and polyatomic ions, formed in the plasma from the matrix constituents.…”
Section: Chemical Analysis Of Prostate Gland Elemental Contentmentioning
confidence: 99%