2019
DOI: 10.1016/j.jobe.2018.09.022
|View full text |Cite
|
Sign up to set email alerts
|

A tuning methodology of Model Predictive Control design for energy efficient building thermal control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
3

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(17 citation statements)
references
References 27 publications
0
14
0
3
Order By: Relevance
“…Conventional gradient descent [20] approach has also been investigated to determine the optimal set of MPC parameters based on process repeatability and pre-defined time-domain specifications. Formulation of the cost function, which has to be minimized to determine the MPC parameters, is a complex process, and several attempts have been reported in the literature [21][22][23]. Customization of this cost function and selection of optimization techniques have brought in a wider variant of MPC tuning strategies.…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Conventional gradient descent [20] approach has also been investigated to determine the optimal set of MPC parameters based on process repeatability and pre-defined time-domain specifications. Formulation of the cost function, which has to be minimized to determine the MPC parameters, is a complex process, and several attempts have been reported in the literature [21][22][23]. Customization of this cost function and selection of optimization techniques have brought in a wider variant of MPC tuning strategies.…”
Section: Related Workmentioning
confidence: 99%
“…The cost functions are formulated as per the available plant knowledge and also using the economic aspects. Maximization of comfort and energy saving [21] are achieved by weight tuning in building thermal/heating, ventilation, and air conditioning (HVAC) [22] control system. Minimization of energy consumption in various domestic appliances like the water heater, air conditioner, and refrigerator had been addressed by weight adjustment in the MPC.…”
Section: Related Workmentioning
confidence: 99%
“…Here the desired temperature for the closed room is called reference temperature T re f , and the switch u represents the internal gain state. With these variables and differentiating with respect to time, the state-space model can then be implemented by Equations (13) and (14):…”
Section: Control Applicationmentioning
confidence: 99%
“…[6,12] use circuits of 4th and 7th order to model single thermal zones, while Refs. [13,14] use simplifications and apply different control techniques.…”
Section: Introductionmentioning
confidence: 99%
“…Por otra parte, los paneles solares también representan una estrategia altamente utilizada [45], en investigaciones como [46] se reportan reducciones del flujo entrante de hasta 38 %, pero que en combinación con techos frescos y verdes puede aumentar, según se reporta en trabajos como [47] y [48]. La reducción del flujo de calor entre un espacio cerrado y el entorno con estrategias pasivas es una importante herramienta, pero muchos investigadores han optado por estrategias activas, enfocándose en controlar de manera eficiente los sistemas de refrigeración y calefacción [49,50,51,52]. Por ejemplo en [4] se analizaron múltiples edificios con diferentes tamaños en Montreal, Canadá.…”
Section: Estado Del Arteunclassified