DOI: 10.4995/thesis/10251/153803
|View full text |Cite
|
Sign up to set email alerts
|

Análisis dinámico del confort en edificios con estrategias de control adaptativo en modos deslizantes

Abstract: Palabras clave: Modelado zonas térmicas, control en modos deslizantes, modelos de escala reducida, confort térmico, soluciones termo-aislantes, modelado por parámetros agrupados .

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
0
0

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 84 publications
0
0
0
Order By: Relevance
“…For the case with two thermal zones, the circuit presented in Figure 2 must be extended to include the second thermal zone; Figure 5 shows the new circuit, taking Tw 2 and T 2 as the temperatures for the second zone. Using the circuit for two thermal zones it is possible to derive Equations ( 9) to (12).…”
Section: Case 1: a Single Thermal Zone (M = 1)mentioning
confidence: 99%
See 1 more Smart Citation
“…For the case with two thermal zones, the circuit presented in Figure 2 must be extended to include the second thermal zone; Figure 5 shows the new circuit, taking Tw 2 and T 2 as the temperatures for the second zone. Using the circuit for two thermal zones it is possible to derive Equations ( 9) to (12).…”
Section: Case 1: a Single Thermal Zone (M = 1)mentioning
confidence: 99%
“…The energy consumption in buildings depends on different factors, such as occupant activity [9] and heating, ventilation and air conditioning (HVAC) systems [10], among others. However, to understand the causes of energy consumption, buildings must be studied individually, taking into account the minimum spaces and energy requirements to ensure occupant comfort [11,12]. In this sense, mathematical models and simulators play an essential role, allowing researchers to analyze different configurations and situations in buildings, including huge interior spaces in buildings [13] or green roofs [14].…”
Section: Introductionmentioning
confidence: 99%
“…The model was adjusted using a database recorded for 5 days, from February 9 to 14, 2019, in Santa Marta city (Colombia) [30]. In this database, the internal and external surface temperatures, environmental temperature, and internal air temperature were registered.…”
Section: Tuning and Analysis Of Mathematical Modelmentioning
confidence: 99%
“…2 , using T exp to represent the experimental temperature recorded at the point i, and T for the simulated temperature at this point [30]. The procedure for adjustion consists in separating the studied period in the day and night and calculating the best value to fit the simulation curves to the experimental data.…”
Section: Tuning and Analysis Of Mathematical Modelmentioning
confidence: 99%
See 1 more Smart Citation