2019
DOI: 10.1021/acs.jafc.8b07163
|View full text |Cite
|
Sign up to set email alerts
|

A Triple Quadrupole and a Hybrid Quadrupole Orbitrap Mass Spectrometer in Comparison for Polyphenol Quantitation

Abstract: Liquid chromatography coupled to low-resolution mass spectrometry (LRMS) has historically been a popular approach for compound quantitation. Recently, high-resolution mass spectrometry (HRMS) technical developments led to the introduction of new approaches for quantitative analysis. Whereas the performances of HRMS have been largely assessed for qualitative purposes, there are still questions about its suitability for quantitative analysis. Several papers on LRMS and HRMS comparison have been published; howeve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 38 publications
0
16
0
Order By: Relevance
“…The chromatographic system was coupled to a Q Exactive hybrid quadrupole-Orbitrap mass spectrometer (Thermo Fisher Scientific) with a heated ESI source. The ESI source parameters were set as reported in our previous work [23]. The detection was conducted in TOP 5 data-dependent acquisition (DDA) mode for low-and high-molecular-weight phenolic compounds.…”
Section: Uhplc-hrms Analysismentioning
confidence: 99%
“…The chromatographic system was coupled to a Q Exactive hybrid quadrupole-Orbitrap mass spectrometer (Thermo Fisher Scientific) with a heated ESI source. The ESI source parameters were set as reported in our previous work [23]. The detection was conducted in TOP 5 data-dependent acquisition (DDA) mode for low-and high-molecular-weight phenolic compounds.…”
Section: Uhplc-hrms Analysismentioning
confidence: 99%
“…The mobile phases consisted of H 2 O/HCOOH (99.9:0.1, v/v; phase A) and ACN/HCOOH (99.9:0.1, v/v; phase B). The elution gradient and ESI source parameters were optimized in our previous studies [25,38]. The chromatographic system was coupled to a Q Exactive Hybrid Quadrupole-Orbitrap Mass Spectrometer (Thermo Fisher Scientific).…”
Section: Uhplc-ms/ms Analysismentioning
confidence: 99%
“…Among these instrumentations, SRM acquisition by QqQ‐MS was a well‐constructed procedure, which was widely applied on the quantitation of polyphenols. In addition, the Orbitrap‐based instrumentations could also provide reproducible results and large linear ranges, but they were rarely investigated for the quantitation of polyphenols …”
Section: Introductionmentioning
confidence: 99%