2019
DOI: 10.1186/s11671-019-3215-4
|View full text |Cite
|
Sign up to set email alerts
|

A Transient-Enhanced Voltage Regulator with Stability and Power-Supply-Rejection Boosting

Abstract: A high-stability voltage regulator (VR) is proposed in this paper, which integrates transient enhancement and overcurrent protection (OCP). Taken into consideration the performance and area advantages of low-voltage devices, most control parts of proposed VR are supplied by the regulated output voltage, which forms self-power technique (SPT) with power supply rejection (PSR) boosting. Besides, the stability and transient response are enhanced by dynamic load technique (DLT). An embedded overcurrent feedback lo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 30 publications
0
3
0
Order By: Relevance
“…The coefficients of A v LR and A v M AL are equated to solve the following equations simultaneously: Then, the physical parameters, i.e., C gs R oa , C gs R oa g m , g m , and G ea g m , are estimated. Thereafter, these estimated physical parameters are substituted into the Z out CL (z) model, as shown in (2). Moreover, parameters that are easy to measure and obtain, such as R 1 , R 2 , C out , and r ds , are also substituted by their measured values in (2).…”
Section: E Physical Parameter Estimationmentioning
confidence: 99%
See 2 more Smart Citations
“…The coefficients of A v LR and A v M AL are equated to solve the following equations simultaneously: Then, the physical parameters, i.e., C gs R oa , C gs R oa g m , g m , and G ea g m , are estimated. Thereafter, these estimated physical parameters are substituted into the Z out CL (z) model, as shown in (2). Moreover, parameters that are easy to measure and obtain, such as R 1 , R 2 , C out , and r ds , are also substituted by their measured values in (2).…”
Section: E Physical Parameter Estimationmentioning
confidence: 99%
“…Thereafter, these estimated physical parameters are substituted into the Z out CL (z) model, as shown in (2). Moreover, parameters that are easy to measure and obtain, such as R 1 , R 2 , C out , and r ds , are also substituted by their measured values in (2). Finally, a complete estimated Z out CL (z) is obtained.…”
Section: E Physical Parameter Estimationmentioning
confidence: 99%
See 1 more Smart Citation