2019
DOI: 10.1016/j.joule.2018.11.017
|View full text |Cite
|
Sign up to set email alerts
|

A Three-Terminal Monolithic Perovskite/Si Tandem Solar Cell Characterization Platform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
97
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 86 publications
(97 citation statements)
references
References 42 publications
0
97
0
Order By: Relevance
“…TPVD analysis and evaluation of the dependence of V OC on the temperature (i.e., V OC -T measurement) were used to investigate the internal recombination kinetics in our CZTSSe devices. 33,34 In Figure 5A, the minority carrier lifetime (or recombination time constant), τ r , obtained by TPVD is plotted as a function of V OC . The CZTSSe thin-film solar cells with PHT had a longer minority carrier lifetime than those without PHT, which is responsible for the enhanced V OC observed in Figure 4A collecting capability.…”
Section: Characterizationmentioning
confidence: 99%
“…TPVD analysis and evaluation of the dependence of V OC on the temperature (i.e., V OC -T measurement) were used to investigate the internal recombination kinetics in our CZTSSe devices. 33,34 In Figure 5A, the minority carrier lifetime (or recombination time constant), τ r , obtained by TPVD is plotted as a function of V OC . The CZTSSe thin-film solar cells with PHT had a longer minority carrier lifetime than those without PHT, which is responsible for the enhanced V OC observed in Figure 4A collecting capability.…”
Section: Characterizationmentioning
confidence: 99%
“…The EQE of 4T tandem was obtained by measuring the EQE of each subcell (as for GaAs bottom‐cell measurement, the perovskite top‐cell was utilized as a filter). The EQE of the 2T tandem cell was measured by three‐terminal mode using ITO intermediate layer between subcells that can provide more accurate EQE signals of top‐ and bottom‐cell without light and potential bias . The transmittance and reflectance were measured using Cary 5000 UV–vis–NIR spectrophotometer with an integrating sphere.…”
Section: Methodsmentioning
confidence: 99%
“…To facilitate or simplify the accurate characterization of monolithic 2T TSCs and circumvent the spectral mismatch issue, researchers designed a three-terminal monolithic tandem configuration and showed precise measurement results. [99][100][101][102]…”
Section: Inorganic Perovskitesmentioning
confidence: 99%