A systematic approach to describe the air terminal device in CFD simulation for room air distribution analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(15 citation statements)
references
References 6 publications
0
15
0
Order By: Relevance
“…Energy saving potential was 20 to 30% at low occupancy open plan office and was 3 to 5% at high occupancy open plan office [17]. In addition, a comparison between DCV-CO 2 and CAV system were conducted in Montreal office building and found energy saving of 12% for DCV-CO 2 over CAV system while keeping same quality of thermal comfort and IAQ [18]. Another study [19] found significant reduction of running cost which was nearly 50% for DCV-CO 2 system compare to fixed outdoor air flow system in high rise multi-zone office building.…”
Section: Page 4 Of 38mentioning
confidence: 97%
See 1 more Smart Citation
“…Energy saving potential was 20 to 30% at low occupancy open plan office and was 3 to 5% at high occupancy open plan office [17]. In addition, a comparison between DCV-CO 2 and CAV system were conducted in Montreal office building and found energy saving of 12% for DCV-CO 2 over CAV system while keeping same quality of thermal comfort and IAQ [18]. Another study [19] found significant reduction of running cost which was nearly 50% for DCV-CO 2 system compare to fixed outdoor air flow system in high rise multi-zone office building.…”
Section: Page 4 Of 38mentioning
confidence: 97%
“…Insert Figure 15 here M a n u s c r i p t 18 To analyze the effect of individual ventilation and cooling, active chilled beams were replaced with ceiling cooling panel in 'Ref.EA.GC Case' and results are shown in Figure 16. The cooling capacity of a ceiling cooling panel did not depend on supply airflow rate that was a feature of active chilled beam cases.…”
Section: Calculation Logic Of the Footprint Is Shown Inmentioning
confidence: 99%
“…This supply air diffuser spreads in all directions and its modelling is complicated. Referring to literature (Huo et al 2000) useful suggestions provided by the method for describing the supply air diffuser boundary conditions were taken into account for the CFD simulation, using the diffuser characteristic jet equations. This allowed comparison of the real data provided by the company on the air inlet velocity and its downward flow from the ceiling with those obtained by first basic simulations (Fig.…”
Section: Solid Modellingmentioning
confidence: 99%
“…Several methods have been developed such as conventional method [14], box method [15], momentum method [16], etc. A series of square four-way ceiling diffuser models which include models A to E are developed and validated recently [17].…”
Section: Article In Pressmentioning
confidence: 99%