2008
DOI: 10.1080/01443610802462092
|View full text |Cite
|
Sign up to set email alerts
|

A survey of methods used to measure symphysis fundal height

Abstract: Symphysis fundal height (SFH) is currently used in the UK as a screening test to identify which pregnancies may require additional investigations including the use of ultrasound fetal biometry. The routine use of SFH has been subjected to extensive research assessing its sensitivity and also inter and intraobserver variation. This study's aim was to assess the current UK practice of SFH measurement and particularly looked at methods used in its measurement. A total of 250 healthcare professionals (doctors and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 16 publications
0
10
0
Order By: Relevance
“…Moreover, unlike Tetschke et al (2016), our work did not require high-resolution input signals, making the implementation of the approach described here feasible in LMICs. Notably, our GA estimations were lower than the 6 weeks error associated with symphysis-fundal height, which is the common dating method used in LMICs to detect IUGR (Griffiths et al, 2008).…”
Section: Interpretations Of Findingsmentioning
confidence: 66%
See 1 more Smart Citation
“…Moreover, unlike Tetschke et al (2016), our work did not require high-resolution input signals, making the implementation of the approach described here feasible in LMICs. Notably, our GA estimations were lower than the 6 weeks error associated with symphysis-fundal height, which is the common dating method used in LMICs to detect IUGR (Griffiths et al, 2008).…”
Section: Interpretations Of Findingsmentioning
confidence: 66%
“…However, the symphysis-fundal height method lacks significant evidence to recommend its widely use in LMICs (World Health Organization, 2016). Moreover, previous studies have noted that the SHF has exhibited a large error of ±6 weeks for estimating GA (Griffiths et al, 2008). New approaches are, therefore, still needed to provide reproducible and low-cost assessment for detecting abnormal growth in settings in which ultrasound images, taken by trained operators, are not available.…”
Section: Introductionmentioning
confidence: 99%
“…Fundal height was measured in centimetres first from the fundus to the top of the symphysis pubis and second from the symphysis pubis to the top of the fundus. Measurements were compared for consistency and then averaged for analyses to improve predictive accuracy by being inclusive of varying measurement techniques . Additional fundal heights were abstracted from the prenatal records.…”
Section: Methodsmentioning
confidence: 99%
“…Measurements were compared for consistency and then averaged for analyses to improve predictive accuracy by being inclusive of varying measurement techniques. 18 Additional fundal heights were abstracted from the prenatal records. Mid-upper arm circumference was measured using a non-stretchable linen tape to the nearest 0.1 cm.…”
Section: Methodsmentioning
confidence: 99%
“…Measurement of fundal height for fetal growth assessment is recommended above other methods, including comparing uterine height with abdominal landmarks and measurement of abdominal circumference (Engstrom and Sittler 1993;NICE 2008). However, the method is recognised as flawed, with rates of sensitivity cited at 40-73% and varying degrees of inter-and intraobserver variation (Griffiths et al 2008). A recent review showed that there is insufficient evidence to fully evaluate the efficacy of symphysis-fundal height measurement, but warned it would be unwise to abandon its use in the absence of proven alternatives (Neilson 2009).…”
Section: Introductionmentioning
confidence: 97%