A study on the operational stability of a refrigeration system having a variable speed compressor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(18 citation statements)
references
References 15 publications
0
18
0
Order By: Relevance
“…Various studies have been conducted on twophased flow patterns of refrigerants. (Haverkamp et al 2006;Chinnov and Kabov 2006;Saisorn and Wongwises 2008;Shao et al 2009; Rebrov 2010; Awad and Muzychka 2014) However, this is not true regarding refrigerant-oil mixtures due to the difficulties found in its evaluation and experimentation. Nonetheless, the changes in flow pattern by the addition of oil can be explained through foaming.…”
Section: Effect Of the Lubricant Oil Mixture In The Superheated Regionmentioning
confidence: 99%
See 1 more Smart Citation
“…Various studies have been conducted on twophased flow patterns of refrigerants. (Haverkamp et al 2006;Chinnov and Kabov 2006;Saisorn and Wongwises 2008;Shao et al 2009; Rebrov 2010; Awad and Muzychka 2014) However, this is not true regarding refrigerant-oil mixtures due to the difficulties found in its evaluation and experimentation. Nonetheless, the changes in flow pattern by the addition of oil can be explained through foaming.…”
Section: Effect Of the Lubricant Oil Mixture In The Superheated Regionmentioning
confidence: 99%
“…Thus, extrapolating a MSS line from one system to another can result in lack of precision. (Chen et al 2008) At the time, the MSS theory was developed for single speed compressors. Varying compressor speed is known to reduce energy consumption in refrigeration systems and it is becoming widely used today.…”
Section: Evaporator Instabilitymentioning
confidence: 99%
“…To improve the energy saving of VCC system under different demands of cooling capacity, appropriate superheat set point based on the current demand of cooling load is determined [14]. The nonlinear relationship between stable superheat degree and cooling load in VCC systems is measured by curve fitting which indicated that when the cooling load is lower than a particular value, the superheat remains at a minimum value; similarly, when the cooling load is greater than a particular value, the superheat degree remains at a maximum value, shown in (5 …”
Section: B Dynamic Model Of Vapor Compression Refrigeration Cyclementioning
confidence: 99%
“…The cause of instability may be explained as the influence of the inherent characteristics of two-phase flow in evaporator and also the impact of the system control characteristics [6]. The former emphasizes particularly on the oscillations of two-phase flow of the refrigerant in evaporation process; its result is regarded as the basis of the system instability.…”
Section: Introductionmentioning
confidence: 99%