2010
DOI: 10.4047/jap.2010.2.3.111
|View full text |Cite
|
Sign up to set email alerts
|

A study on thein-vitrowear of the natural tooth structure by opposing zirconia or dental porcelain

Abstract: PURPOSEThis study was conducted to evaluate clinical validity of a zirconia full-coverage crown by comparing zirconia's wear capacity over antagonistic teeth with that of feldspathic dental porcelain.MATERIALS AND METHODSThe subject groups were divided into three groups: the polished feldspathic dental porcelain group (Group 1), the polished zirconia group (Group 2), and the polished zirconia with glazing group (Group 3). Twenty specimens were prepared from each group. Each procedure such as plasticity, conden… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
157
2
8

Year Published

2013
2013
2018
2018

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 173 publications
(181 citation statements)
references
References 22 publications
2
157
2
8
Order By: Relevance
“…3a). As opposed to findings in other laboratory studies (Jung et al, 2010;Preis et al, 2012;Rosentritt et al, 2012) the wear of enamel antagonists by feldspathic ceramic (VM) and glass ceramic (EC) was not significantly different from that of zirconium dioxide ceramics (Tab. 2).…”
Section: Two-body Wear Of Silicate and Hybrid Ceramicscontrasting
confidence: 86%
See 1 more Smart Citation
“…3a). As opposed to findings in other laboratory studies (Jung et al, 2010;Preis et al, 2012;Rosentritt et al, 2012) the wear of enamel antagonists by feldspathic ceramic (VM) and glass ceramic (EC) was not significantly different from that of zirconium dioxide ceramics (Tab. 2).…”
Section: Two-body Wear Of Silicate and Hybrid Ceramicscontrasting
confidence: 86%
“…The zero m-wear for monolithic zirconium dioxide ceramics (IN) and minimal a-wear (25.5 µm) of its enamel antagonists both impressed ( Fig.1; Table 2), even though these properties have already been reported for zirconium dioxide ceramics by recent laboratory studies (Jung et al, 2010;Preis et al, 2012;Rosentritt et al, 2012;Stawarczyk et al, 2012). The contact area of IN looked slightly polished at the end of the test, while, other than the rougher contact areas of the control facets of a-enamel against m-enamel (Fig.…”
Section: Two-body Wear Of Zirconium Dioxide Ceramicsmentioning
confidence: 80%
“…As expected for a composite material, the properties are intermediate between those of ceramics and particle-filled resins. 60,61,63 The elastic modulus of these materials is in the range of 30 GPa, which is half of that reported for conventional veneering ceramics but closer to what is usually reported for dentin (15)(16)(17)(18)(19)(20). 58,63 Typical ceramic materials have a higher elastic modulus values than PICN 64 .…”
Section: Polymer Infiltrated Ceramic Network (Picns)mentioning
confidence: 62%
“…Some of these studies compared different surface finishing techniques for monolithic zirconia restorations, such as polishing versus glazing, and found that polished surfaces resulted in less enamel wear of the antagonist. 13,14,15,16 It is needless to say that the high surface hardness of zirconia has a major influence on the antagonist wear and a perfect polish of any monolithic zirconia restoration is therefore very important. A clinical study evaluated the occlusal surface wear of monolithic zirconia crowns placed in premolars and molars.…”
Section: Monolithic Zirconia Restorationsmentioning
confidence: 99%
“…Buccal cusps of extracted upper premolar teeth were sectioned and used as an antagonist in a chewing simulation. For oneyear, thermo-mechanic simulation, 240,000 load cycles with a load of 49 N and a frequency of 1.7 Hz, were applied through 1.5 mm horizontal and 3 mm vertical movement of the antagonist on the center of the sealed occlusal surfaces 13) . Specimens were also subjected to thermocycling (1,000 cycles of 5 and 55°C; 100 s per cycle, and a 10-s interval to remove water from the chambers) at the same time with the chewing simulation.…”
Section: Artificial Agingmentioning
confidence: 99%