2018 25th IEEE International Conference on Image Processing (ICIP) 2018
DOI: 10.1109/icip.2018.8451583
|View full text |Cite
|
Sign up to set email alerts
|

A Study on the 4D Sparsity of JPEG Pleno Light Fields Using the Discrete Cosine Transform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
10
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 3 publications
2
10
0
1
Order By: Relevance
“…3 leads to the conclusion that for the lenslet LFs Bikes and Fountain, the energy decay is much slower along the (u, v) coordinates than along the (s, t) coordinates. Since the faster the 4D-DCT coefficients energy decay along a direction, the larger the redundancy along this direction, these results are coherent with the findings in [31], which state that for lenslet LFs the inter-view redundancy tends to be larger than the intraview redundancy. On the other hand, for the more sparsely angular sampled LFs Greek and Set2 2K sub, the energy decay along the (s, t) coordinates tends to be much slower than for the lenslet LFs.…”
Section: ) 4d-dct Coefficients Energy Distribution For Densely Angulsupporting
confidence: 87%
See 3 more Smart Citations
“…3 leads to the conclusion that for the lenslet LFs Bikes and Fountain, the energy decay is much slower along the (u, v) coordinates than along the (s, t) coordinates. Since the faster the 4D-DCT coefficients energy decay along a direction, the larger the redundancy along this direction, these results are coherent with the findings in [31], which state that for lenslet LFs the inter-view redundancy tends to be larger than the intraview redundancy. On the other hand, for the more sparsely angular sampled LFs Greek and Set2 2K sub, the energy decay along the (s, t) coordinates tends to be much slower than for the lenslet LFs.…”
Section: ) 4d-dct Coefficients Energy Distribution For Densely Angulsupporting
confidence: 87%
“…This is equivalent to saying that the 4D-DCT energy compaction properties are poorer for such LFs, which is mainly due to the larger baseline. These results are again coherent with the findings in [31]. Such poor energy compaction property of the 4D-DCT for the LFs which angular sampling is more sparse (non-lenslet) is the main reason why the JPEG Pleno 4D-Transform coding mode [37] performs better for lenslet LFs.…”
Section: ) 4d-dct Coefficients Energy Distribution For Densely Angulsupporting
confidence: 85%
See 2 more Smart Citations
“…Porém, a representação mais natural de um light field parece ser por meio de uma estrutura 4-dimensional, com duas dimensões para o plano das vistas e outras duas para o plano espacial da imagem. Tal possibilidadeé considerada em [11], em que se demonstra que, usando a 4D-DCT, conseguese explorar com maior eficiência a redundância presente na estrutura de um light field lenslet do que usando suas versões bidimensionais. Essa conclusão deu suporte para que, em [12], fosse proposto um CODEC para imagens lenslet de light fields utilizando a 4D-DCT, explorando a alta correlação entre as vistas e o plano espacial.…”
Section: Introductionunclassified