2002
DOI: 10.1016/s0003-2670(02)00048-x
|View full text |Cite
|
Sign up to set email alerts
|

A study of microdialysis sampling of metal ions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
1

Year Published

2003
2003
2017
2017

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(27 citation statements)
references
References 26 publications
0
26
1
Order By: Relevance
“…fermentations), [21,22] the assessment of the quality of foodstuffs [23][24][25] and cosmetics [26,27] and the probing of target species in environmentally relevant matrices. [16,[28][29][30][31][32][33][34][35][36][37][38] Such measurements are based on the deployment of a semi-permeable hydrophilic membrane into the target medium. The device thus acts as a diffusion-controlled passive micro-sampler.…”
Section: Introductionmentioning
confidence: 99%
“…fermentations), [21,22] the assessment of the quality of foodstuffs [23][24][25] and cosmetics [26,27] and the probing of target species in environmentally relevant matrices. [16,[28][29][30][31][32][33][34][35][36][37][38] Such measurements are based on the deployment of a semi-permeable hydrophilic membrane into the target medium. The device thus acts as a diffusion-controlled passive micro-sampler.…”
Section: Introductionmentioning
confidence: 99%
“…For instance, fluoroquinolones were separated, utilizing a 15-kDa cellulose probe, in eggs 42 and in chicken liver and muscle, 43 metal ions in tomatoes 44 with a polyethersulfone membrane of 30-kDa cutoff, glucose, galactose, and lactose in milk 45 using a 20-kDa polyarylethersulfone (PAES) probe, catechins in tea 46 with a 13-kDa regenerated cellulose probe, and sinigrin in seeds of cruciferous vegetables (brussels, cauliflower, and cabbage) 47 with a 5-kDa cellulose acetate probe.…”
Section: Dialysis and Microdialysismentioning
confidence: 99%
“…However, the literature is lacking reports on the analysis of metal ions and MD. Ion chromatography, inductively coupled plasma-MS and recently CE have been used for the determination of metal ions [63]. Studies involving the metal ion uptake in nature and the quantification of metal ions in the bloodstream could benefit from the application of MD sampling.…”
Section: Other Analytical Techniques Used In MDmentioning
confidence: 99%
“…Torto et al [63] carried out a study on the extraction fraction of metal ions Cd, Cr, Cu, Ni and Pb sampled by MD from a quiescent aqueous solution. A Varian AA-400 plus electro-thermal atomic absorption spectrometer, fitted with a Varian GTA-96 graphite tube atomiser, Zeeman background corrector and an auto-sampler were used.…”
Section: Other Analytical Techniques Used In MDmentioning
confidence: 99%