1998
DOI: 10.1016/s0890-6955(97)00055-2
|View full text |Cite
|
Sign up to set email alerts
|

A six-degree-of-freedom measurement system for the motion accuracy of linear stages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
31
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 96 publications
(31 citation statements)
references
References 3 publications
0
31
0
Order By: Relevance
“…According to Section 3.C and Section 2 (the roll measurement part), the influence of the roll on the vertical straightness [Eq. (12)] and the principle of the roll measurement [Eq. (3)] are both taken into account; then we will obtain γ m 2d r sin γ 2bcos γ − 1 D ;…”
Section: Crosstalk Compensation Between the Real Value And Measurementioning
confidence: 99%
See 2 more Smart Citations
“…According to Section 3.C and Section 2 (the roll measurement part), the influence of the roll on the vertical straightness [Eq. (12)] and the principle of the roll measurement [Eq. (3)] are both taken into account; then we will obtain γ m 2d r sin γ 2bcos γ − 1 D ;…”
Section: Crosstalk Compensation Between the Real Value And Measurementioning
confidence: 99%
“…Hence, for the roll crosstalk to the vertical straightness, each QD has its own compensation model, as described in Eq. (12). When the roll is introduced with a range of 70 00 , the results for each QD are shown in Fig.…”
Section: Compensation Experiments For Roll Crosstalk To the Two-directmentioning
confidence: 99%
See 1 more Smart Citation
“…The resolution of these measurement devices can reach the nanometric level and even the sub-nanometric level. Heterodyne interferometry is inherently more accurate than standard interferometry because it is less sensitive to intensity noise [2,3].…”
Section: Introductionmentioning
confidence: 99%
“…The whole measurement period is long and efficiency is low as only one error is measured after setting and adjusting one time. At present, many methods of multi-degree-of-freedom measurement simultaneously are used such as geometrical optical measurement method [1] ,diffraction measurement method [2] ,laser tracking method [3] ,laser interference with collimation method [4] ,three parallel beams method [5] , holographic lens prismatic method [6] and double-CCD method [7] . However, complex configurations, high costs and low measurement precisions are the shortcomings of these methods.…”
mentioning
confidence: 99%