A single‐sample method to determine the hydroxyl values of polyols using mid‐FTIR spectroscopy

Abstract: A single‐sample Fourier transform infrared (FTIR) method suitable for automation was developed to determine the hydroxyl value (OHV) of lipid‐based polyols. It is a modification of the original split‐sample FTIR method using the reaction of p‐toluenesulfonyl isocyanate (TSI) with OH groups and measures the carbamate band formed in the differential spectrum before and after the reaction. In the new method, the TSI‐isocyanate absorption is measured before and after the reaction, the area change being proportiona… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…ASTM E1899-08 potentiometric titration standard method was used to determine the free hydroxyl (−OH) groups in PU structures . In this method, potassium hydrogen phthalate (KHP) was used to determine the correlation factor ( f ) of the standard.…”
Section: Methodsmentioning
confidence: 99%
“…ASTM E1899-08 potentiometric titration standard method was used to determine the free hydroxyl (−OH) groups in PU structures . In this method, potassium hydrogen phthalate (KHP) was used to determine the correlation factor ( f ) of the standard.…”
Section: Methodsmentioning
confidence: 99%
“…Calibrations were done according to changes in FTIR spectra. 95 The epoxy oxygen percentage, or the mass fraction of oxygen in epoxides relative to total oxygen in epoxidized oil, can be determined through titration. To calculate oxirane content, relative conversion to oxirane is measured.…”
Section: Factor Affecting Epoxidation 41 | Oxirane Content and Select...mentioning
confidence: 99%
“…Absorption in FTIR shows bands near 1497 and 862–762 cm −1 , and determinations were made using the baseline method. Calibrations were done according to changes in FTIR spectra 95 …”
Section: Factor Affecting Epoxidationmentioning
confidence: 99%
“…This method involved the reaction of toluenesulfonyl isocyanate (TSI) with alcohol groups (R-OH) to produce its corresponding carbamate, however, TSI also reacts with moisture (H-OH) to produce CO 2 and an amide. This observation led to carrying out the TSI-H 2 O reaction in a septum-sealed vials and measuring the CO 2 generated [49] spectrally. The approach was demonstrated to have similar sensitivity and accuracy as KF analysis, gravimetric moisture calibrations covering 0-100 ppm having SDs of <1 ppm.…”
Section: Ftir H 2 O Analysismentioning
confidence: 99%