A simple versatile sample holder of low heat capacity for adiabetic calorimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

1983
1983
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(8 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…In the temperature range 2 K <~ T~< 100 K the specific heat was determined with an automated adiabatic calorimeter [11] equipped with a high reproducibility sample holder of the sapphire platform type [12]. For thermometry a commercially available germanium resistor was taken; the calorimetric accuracy is currently checked by measuring a standard copper sample.…”
Section: Specific Heatmentioning
confidence: 99%
“…In the temperature range 2 K <~ T~< 100 K the specific heat was determined with an automated adiabatic calorimeter [11] equipped with a high reproducibility sample holder of the sapphire platform type [12]. For thermometry a commercially available germanium resistor was taken; the calorimetric accuracy is currently checked by measuring a standard copper sample.…”
Section: Specific Heatmentioning
confidence: 99%
“…The magnetization of the quartz glass tube was determined in separate runs and subtracted. The heat capacity of powder samples ( m = 260 mg) was measured in a home‐built fully automated double‐shield Nernst adiabatic calorimeter similar to that described in detail by Gmelin et al The sample was encapsulated in Duran glass flasks under ca. 900 mbar helium atmosphere to enable thermal equilibration and attached with a minute amount of Apiezon N vacuum grease to a sapphire platform which carries a thin‐film stainless steel heater and a calibrated Cernox thermometer (CX 1050, Lake Shore Cryotronics, Inc., Westerville OH).…”
Section: Methodsmentioning
confidence: 99%
“…The sample holder consists of a sapphire plate equipped with an electrical heater resistor and a commercially calibrated Ge resistance thermometer (Cryocal). The samples were mounted onto the calorimetric sample holder [29] with a minute amount (2 to 4 mg) of Apiezon N grease. The heat capacity of the sample holder platform, determined in a separate run, and of the grease [30] were subtracted from the total measured heat capacity.…”
Section: Methodsmentioning
confidence: 99%