2014
DOI: 10.1093/chromsci/bmu036
|View full text |Cite
|
Sign up to set email alerts
|

A Simple, Rapid and Eco-Friendly Approach for the Analysis of Aromatic Amines in Environmental Water Using Single-Drop Microextraction-Gas Chromatography

Abstract: Single-drop microextraction (SDME) coupled with gas chromatography-flame ionization detector (GC-FID) was developed for the extraction and determination of aromatic amines (AAs) in environmental water samples. A silicon tube was introduced for the SDME procedure by inserting it into the needle of the micro-injector. In this manner, a large volume of extractant is allowed to be suspended for the extraction, leading to the enhancement of method sensitivity and reproducibility. Extraction parameters which control… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 30 publications
0
3
0
Order By: Relevance
“…After selecting an optimal derivatization/extraction temperature, PFBAY loading time and amine derivatization/extraction time were further optimized with the purpose of achieving an acceptable compromise between sensitivity (dependent on derivatization reaction yields) and total analysis time. Three different PFBAY loading times (5, 10, and 15 min) as well as three reaction times (30,45, and 60 min) were investigated. Generally, longer reaction times led to higher yields of derivatives.…”
Section: Derivatization Reaction Procedures Optimization In Gas Phasementioning
confidence: 99%
See 2 more Smart Citations
“…After selecting an optimal derivatization/extraction temperature, PFBAY loading time and amine derivatization/extraction time were further optimized with the purpose of achieving an acceptable compromise between sensitivity (dependent on derivatization reaction yields) and total analysis time. Three different PFBAY loading times (5, 10, and 15 min) as well as three reaction times (30,45, and 60 min) were investigated. Generally, longer reaction times led to higher yields of derivatives.…”
Section: Derivatization Reaction Procedures Optimization In Gas Phasementioning
confidence: 99%
“…Sample pH did not exceed 10 as a mean to avoid precocious deterioration of the coatings used [15,21]. PFBAY loading time was maintained constant at 10 min, while different extraction/reaction times of 15,30,45, and 60 min were tested in aqueous solution, in order to take into account for the different diffusivity of the analytes in gas and liquid phase.…”
Section: Optimization Of Reaction Conditions In Aqueous Phasementioning
confidence: 99%
See 1 more Smart Citation