2022
DOI: 10.3390/analytica3020018
|View full text |Cite
|
Sign up to set email alerts
|

A Simple and Reliable Liquid Chromatographic Method for Simultaneous Determination of Five Benzodiazepine Drugs in Human Plasma

Abstract: Benzodiazepines (BZDs) are one of the most important drugs that have been used in the treatment of neuropsychological disorders. Indeed, BZDs are abused by drug addicts regardless of their therapeutic uses. Therefore, it was important in forensic and clinical toxicology to reach an easy and reliable method for the screening and quantification of BZDs in the human plasma matrix. In the current work, five BZDs, namely bromazepam, clonazepam, lorazepam, nordiazepam and diazepam were simultaneously separated and d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 34 publications
0
2
0
Order By: Relevance
“…Table 5 shows a statistical study of the results obtained for the assay of BRZ in pure form using the cited method versus results obtained using a published HPLC technique [ 23 ]. The calculated t and F values are lower than the tabulated ones, indicating that there is no substantial difference in accuracy and precision between the two approaches.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Table 5 shows a statistical study of the results obtained for the assay of BRZ in pure form using the cited method versus results obtained using a published HPLC technique [ 23 ]. The calculated t and F values are lower than the tabulated ones, indicating that there is no substantial difference in accuracy and precision between the two approaches.…”
Section: Resultsmentioning
confidence: 99%
“…Many analytical techniques have been reported in the literature for the assay of BRZ either alone or in conjunction with other drugs in dosage form and/or body fluids. These techniques include ultraviolet (UV)–visible spectroscopy [ 8 , 9 , 10 , 11 , 12 ], fluorimetry [ 8 , 13 ], liquid chromatography (LC) [ 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 ], gas chromatography connected to mass spectrometry (GS/MS) [ 27 , 28 , 29 ], and capillary electrophoresis (CE) [ 30 , 31 ]. Potentiometric membrane sensors, either inner liquid [ 32 , 33 , 34 ] or solid-contact electrodes [ 35 ], were used for the determination of BRZ in its tablet form, biological fluids, and wastewater effluents.…”
Section: Introductionmentioning
confidence: 99%