2018
DOI: 10.2174/1573412913666170613091914
|View full text |Cite
|
Sign up to set email alerts
|

A Simple and Rapid HPLC Method for the Multidetermination of Enrofloxacin, Ciprofloxacin, and Oxytetracyclin in Raw Materials and Veterinary Pharmaceutical Formulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…The analysis was carried out in an isocratic mode at the flow rate of 1.0 ml/min, at 25 °C and detection was carried out at 270 nm. Good linearity with the coefficient of correlation 0.9991 indicated that the proposed method was linear within the range of 0.1-0.6µg/ml compared to prevaling method having linearity with a coefficient of correlation 0.9961 and flow rate of 3.0 ml/min [12]. Accuracy results displayed good reproducibility with % RSD below 2%.…”
Section: Estimationmentioning
confidence: 89%
See 1 more Smart Citation
“…The analysis was carried out in an isocratic mode at the flow rate of 1.0 ml/min, at 25 °C and detection was carried out at 270 nm. Good linearity with the coefficient of correlation 0.9991 indicated that the proposed method was linear within the range of 0.1-0.6µg/ml compared to prevaling method having linearity with a coefficient of correlation 0.9961 and flow rate of 3.0 ml/min [12]. Accuracy results displayed good reproducibility with % RSD below 2%.…”
Section: Estimationmentioning
confidence: 89%
“…The methods available for Enrofloxacin estimation are thin-layer chromatography (TLC)-fluorescence, capillary electrophoresis-fluorescence, Spectrophotometry [7,8], high-performance liquid chromatography (HPLC)-UV or fluorescence [9][10][11][12][13][14][15][16][17], HPLC-Mass spectrometry (MS) or gas chromatography (GC)-MS [18]. The majority of these methods have been developed to analyze biological samples such as serum or urine.…”
Section: Introductionmentioning
confidence: 99%
“…The regression equations obtained were y = 0.1302x -0.03378 and y = 0.1336x -0.0088 for TC, and formulation contain-ing TC, respectively. The correlation coefficients (r) of the calibration curves were 0.999 both for TC, and for formulation containing TC, according to RDC 166 (ANVISA, 2017) (17,18,19) minimum acceptable criterion (Figure 3).…”
Section: Linearitymentioning