1991
DOI: 10.1007/bf00233860
|View full text |Cite
|
Sign up to set email alerts
|

A simple and disposable sweat collector

Abstract: Apart from in cystic fibrosis, where sweat analysis provides valuable diagnostic information, sweat yields remain an overlooked biological fluid. Technical problems (dilution, condensation, contamination, evaporation, etc.) linked to currently available collection procedures are of concern and thwart their use. To overcome some of these technical difficulties, an original sweat-collection technique is described. A collection capsule is created inside a flexible, adhesive and disposable anchoring membrane paste… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
42
0
1

Year Published

2004
2004
2020
2020

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(43 citation statements)
references
References 6 publications
0
42
0
1
Order By: Relevance
“…To extract the sweat, the patches were then centrifuged and the spun and sweat was collected in a sterile tube (Marques-Deak et al 2006;Sarno et al 2001). It is possible that the resultant sweat available for analysis contains some contamination from the absorbent pad and may give rise to false positive or false negative results (Brisson et al 1991). In the present study, this issue was circumvented by allowing the sweat to pool during the collection period before aspiration, thus negating any potential contamination from collection pads (Boysen et al 1984).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To extract the sweat, the patches were then centrifuged and the spun and sweat was collected in a sterile tube (Marques-Deak et al 2006;Sarno et al 2001). It is possible that the resultant sweat available for analysis contains some contamination from the absorbent pad and may give rise to false positive or false negative results (Brisson et al 1991). In the present study, this issue was circumvented by allowing the sweat to pool during the collection period before aspiration, thus negating any potential contamination from collection pads (Boysen et al 1984).…”
Section: Discussionmentioning
confidence: 99%
“…The previously published disposable sweat collection method was used to obtain sweat samples (Brisson et al 1991). Briefly, on a clean working surface using gloved hands, a sweat patch consisting of laboratory film paper (Parafilm, American Can Co.) was attached to the adhesive side of a sterile wound dressing (Opsite, Smith & Nephew) to form a collection chamber once applied to the skin surface.…”
Section: Sweat Collectionmentioning
confidence: 99%
“…However, this method has been found to generate results with a high coefficient of variation, and attention has moved to sweat collection patches or capsules [7]. For example, a disposable sweat collector developed by Brisson et al consisted of a capsule, created inside a flexible adhesive membrane pasted onto the skin [8]. The collected samples were then stored at low temperatures for subsequent analysis in the laboratory.…”
Section: Introductionmentioning
confidence: 99%
“…The method has been found to generate results with a high coefficient of variation, which has lead to the development of sweat collection patches or capsules [22]. For example, a disposable sweat collector developed by Brisson et al consisted of capsule, created inside a flexible adhesive membrane pasted onto the skin [23]. These collected samples are then stored at low temperatures for later analysis in a laboratory.…”
mentioning
confidence: 99%