1990
DOI: 10.1109/14.64506
|View full text |Cite
|
Sign up to set email alerts
|

A short method of estimating lifetime of polypropylene film using step-stress tests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

1992
1992
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(12 citation statements)
references
References 7 publications
0
12
0
Order By: Relevance
“…Since the voltage procedure of protocol 1 is the same as that of [2], and that of protocol 2 is the same as that of [7], the data is also analysed by their methods. The ageing parameters obtained by the different methods are listed in Table 4 It can be seen that the ageing parameters obtained by the new method are quite close to each other, while the ageing parameters obtained by the other two methods have a greater difference.…”
Section: Protocol 1: Constant Voltage Stepmentioning
confidence: 99%
See 2 more Smart Citations
“…Since the voltage procedure of protocol 1 is the same as that of [2], and that of protocol 2 is the same as that of [7], the data is also analysed by their methods. The ageing parameters obtained by the different methods are listed in Table 4 It can be seen that the ageing parameters obtained by the new method are quite close to each other, while the ageing parameters obtained by the other two methods have a greater difference.…”
Section: Protocol 1: Constant Voltage Stepmentioning
confidence: 99%
“…The material is usually designed to withstand the voltage stress for decades of years. In order to obtain the reliability of the design, accelerated life tests are usually taken under constant higher voltage stress based on the empirical model: the inverse power low (t L ·V n = constant) and the exponential low (c·exp(-k·V)=constant) [2].However, there still is not a unified standard for testing high voltage DC extruded cable systems, only a recommendation. Furthermore the recommendation only gives a lower limit of ageing parameter (n=10 in the inverse power law), which directly determines the voltage used in the test [3].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Performances of partial discharges in oilpaper insulation and dissolved gases in insulating oils under pulsating DC voltages were introduced in [14]. Time to breakdown and lifetime models of oil-immersed insulation systems for HVDC converter transformers were presented in [15,16]. However, there are very few published works on the electrical breakdown properties and lifetime models of oilpaper insulation under combined voltage stresses and at various temperatures.…”
Section: Introductionmentioning
confidence: 98%
“…The step-up voltage application method is used to acquire sufficient measurement data efficiently. This method is capable of damaging the oil-paper insulation in the same extent compared with the constant voltage application method [19][20][21].…”
Section: Voltage Application Methodsmentioning
confidence: 99%