2011
DOI: 10.1109/tpwrd.2010.2078838
|View full text |Cite
|
Sign up to set email alerts
|

A Selective Harmonic Amplification Method for Reduction of kVA Rating of Current Source Converters in Shunt Active Power Filters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(14 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…Triplen harmonics, such as the 3rd, 9th, and 15th, will be cancelled out in line-to-line voltage waveforms although they are present in line-to-neutral voltage waveforms. There will be no even-order characteristic power system harmonics, such as the 2nd, 4th, 6th, 8th, etc., in line-to-neutral voltage waveforms because of the quarter-wave odd symmetry [24,27,35,36]. The converter's switching frequency fc can be expressed as in (1) for TLN1 and TLN2 techniques:…”
Section: Switching Techniques For Shemmentioning
confidence: 99%
“…Triplen harmonics, such as the 3rd, 9th, and 15th, will be cancelled out in line-to-line voltage waveforms although they are present in line-to-neutral voltage waveforms. There will be no even-order characteristic power system harmonics, such as the 2nd, 4th, 6th, 8th, etc., in line-to-neutral voltage waveforms because of the quarter-wave odd symmetry [24,27,35,36]. The converter's switching frequency fc can be expressed as in (1) for TLN1 and TLN2 techniques:…”
Section: Switching Techniques For Shemmentioning
confidence: 99%
“…, , load load load Figure 3 Flow diagram of the harmonic compensation selection algorithm As seen in Figure 4 the load current _ abc load i is measured and fed to the multiple synchronous reference frames [5]- [8]. Each frame provides the d-q components of each harmonic plus an ac signal.…”
Section: The Srf Algorithm For Individual Harmonic Control In a Vsimentioning
confidence: 99%
“…Figure 1. Owing to the nature of the current-and voltagesourced inverters, insulated gate bipolar transistors (IGBTs) for use in voltage-sourced SAPFs are produced by many semiconductor companies because they exhibit an antishunt diode structure, they can be produced easily, and their losses can be optimized [16]. As the loss of the reactor in the DC linkage of a current-sourced inverter is higher than that of the capacitor in a voltage-sourced inverter, voltage-sourced inverters are used more commonly.…”
Section: Passive Vs Active Filtersmentioning