2022
DOI: 10.1039/d2re00167e
|View full text |Cite|
|
Sign up to set email alerts
|

A scalable twin surface dielectric barrier discharge system for pollution remediation at high gas flow rates

Abstract: In this work, a modular, multi-electrode surface dielectric barrier discharge system for the decomposition of polluted air streams at high volumetric flows, necessary for industrial applications, is designed and constructed....

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(12 citation statements)
references
References 41 publications
1
11
0
Order By: Relevance
“…This results in the discharge current forming a broad peak over the course of the discharge phase instead of the typical behavior of individual filaments. The merging of these individual filaments into a single broad peak has been observed previously in the literature [11]Figure 6b shows the resulting Lissajous figure after taking into account the voltage drop through the equivalent series resistance and the resulting linear fits for each section. The linear fit is effective for the large majority of the on-cycle of the Lissajous figure, and only at the very beginning of the discharge does the fit deviate.…”
Section: Analysis Of Simple Rectangular Electrodessupporting
confidence: 68%
See 4 more Smart Citations
“…This results in the discharge current forming a broad peak over the course of the discharge phase instead of the typical behavior of individual filaments. The merging of these individual filaments into a single broad peak has been observed previously in the literature [11]Figure 6b shows the resulting Lissajous figure after taking into account the voltage drop through the equivalent series resistance and the resulting linear fits for each section. The linear fit is effective for the large majority of the on-cycle of the Lissajous figure, and only at the very beginning of the discharge does the fit deviate.…”
Section: Analysis Of Simple Rectangular Electrodessupporting
confidence: 68%
“…Other manufacturing procedures that do not rely on adhesives have not reported a considerable equivalent series resistance. [11] This measured resistance demonstrates the importance of taking an off measurement at a lower voltage whenever possible. If there is no resistance, voltage and current should show a 90-degree phase shift while the charge and voltage should be perfectly in phase representing an ideal capacitor.…”
Section: Circuit Modelmentioning
confidence: 93%
See 3 more Smart Citations