2018
DOI: 10.1371/journal.pone.0192203
|View full text |Cite|
|
Sign up to set email alerts
|

A robust technique based on VLM and Frangi filter for retinal vessel extraction and denoising

Abstract: The exploration of retinal vessel structure is colossally important on account of numerous diseases including stroke, Diabetic Retinopathy (DR) and coronary heart diseases, which can damage the retinal vessel structure. The retinal vascular network is very hard to be extracted due to its spreading and diminishing geometry and contrast variation in an image. The proposed technique consists of unique parallel processes for denoising and extraction of blood vessels in retinal images. In the preprocessing section,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(14 citation statements)
references
References 46 publications
0
12
0
Order By: Relevance
“…Performance measurement is done by using two datasets, namely DRIVE and STARE. Performance parameters are measured by reference to equations (15)(16)(17), namely sensitivity, specificity, and AUC. The data used amounted to 20 retinal images, the results of segmentation using the proposed model were compared with the results of segmentation done manually by experts available in both datasets.…”
Section: A Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Performance measurement is done by using two datasets, namely DRIVE and STARE. Performance parameters are measured by reference to equations (15)(16)(17), namely sensitivity, specificity, and AUC. The data used amounted to 20 retinal images, the results of segmentation using the proposed model were compared with the results of segmentation done manually by experts available in both datasets.…”
Section: A Resultsmentioning
confidence: 99%
“…The parameters used are sensitivity, specificity, accuracy, and area under the curve. These parameters can be shown in a formula in equations (15)(16)(17). Testing is done using two datasets, namely DRIVE and STARE.…”
Section: F Performance Analysismentioning
confidence: 99%
“…AngioTool is open-source software using a fast, multiscale, Hessian-based filter with a fast recursive Gaussian filter for enhancement of the vessel structure. 9 , 10 , 16 , 17 After vessel segmentation, the image was skeletonized and the morphometric parameters were analyzed. The recursive Gaussian filter is applied to choose the optimal size of the vessels to be measured, which is specified as the vessel thickness on the graphical user interface (GUI).…”
Section: Discussionmentioning
confidence: 99%
“…The max is the maximum, the min is the minimum value, and the average is the gray level. And y (m, n) is the center of manipulation of the median filter [13]. The median filter will see the pixel value of its neighbor and will match the pixel value that will be represented by the neighbor's pixel value.…”
Section: B Median Filtermentioning
confidence: 99%