2021
DOI: 10.1049/hve2.12155
|View full text |Cite
|
Sign up to set email alerts
|

A review: Research on corrosive sulphur in electrical power equipment

Abstract: Corrosive sulphur has been commonly regarded as an enormous threat to electrical power equipment in recent decades. Cuprous sulphide (Cu 2 S) deposition on the insulating oil and paper insulation caused by sulphur corrosion will bring about insulation deteriorations or failures in power transformers and shunt reactors. A large number of experiments have been carried out to investigate sulphur corrosion and some measures have been come up to solve this issue such as replacement of insulating oil, chemical remov… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 100 publications
0
7
0
Order By: Relevance
“…During the corrosion test, the ageing products of insulating oil and paper promote the −CH 3 of TTA‐Cu and the free long chain to break and dissociate to C· and H· in the oil. The ageing product of oil‐paper (RCOO−H) [33] can provide H· and generate H 2 with the H·in the oil. The C· in the oil combines with dissolved oxygen to generate CO and CO 2 .…”
Section: Resultsmentioning
confidence: 99%
“…During the corrosion test, the ageing products of insulating oil and paper promote the −CH 3 of TTA‐Cu and the free long chain to break and dissociate to C· and H· in the oil. The ageing product of oil‐paper (RCOO−H) [33] can provide H· and generate H 2 with the H·in the oil. The C· in the oil combines with dissolved oxygen to generate CO and CO 2 .…”
Section: Resultsmentioning
confidence: 99%
“…Safe, reliable, and economical power supply is the primary goal of the power industry; power transformer is the key power transmission and transformation equipment in the power system [1][2][3][4]. The healthy state of transformer equipment directly affects the safe and stable operation of power system; it will bring largescale power paralysis and huge economic losses once serious transformer fault occurs [5][6][7]. Internal insulation fault is the main cause of transformer fault, the internal insulation system is the composite insulation of insulating oil and insulating paper@paperboard for the oil immersed transformer widely used in power grid [8][9][10].…”
Section: Introductionmentioning
confidence: 99%
“…Nowadays, the sulfur corrosion problem of power equipment has received widespread concern [1][2][3][4][5]. The failures caused by corrosive sulfur greatly affect the safety and stability of the power system and result in substantial economic losses.…”
Section: Introductionmentioning
confidence: 99%