2013
DOI: 10.1109/tmm.2013.2244869
|View full text |Cite
|
Sign up to set email alerts
|

A Review of Recent Advances in Registration Techniques Applied to Minimally Invasive Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
30
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 58 publications
(30 citation statements)
references
References 143 publications
0
30
0
Order By: Relevance
“…The classical application of medical image registration is to align images from different modalities, e.g., pre-operative 3D CT images and intra-operative 2D X-ray projection images [141]. We can distinguish between different types of registration, depending on the dimensionality of the underlying images (2D slice, 3D volumetric, video), as reviewed in [121].…”
Section: Image Registration and Tissue Deformation Trackingmentioning
confidence: 99%
“…The classical application of medical image registration is to align images from different modalities, e.g., pre-operative 3D CT images and intra-operative 2D X-ray projection images [141]. We can distinguish between different types of registration, depending on the dimensionality of the underlying images (2D slice, 3D volumetric, video), as reviewed in [121].…”
Section: Image Registration and Tissue Deformation Trackingmentioning
confidence: 99%
“…One can cite, for example, image guided surgeries and therapies [7], biopsies [46], tracking of particular organs [12] and minimally-invasive procedures [28,17]. In such a context, slice-to-volume registration is a key element for bringing high resolution annotated data into the operating room.…”
Section: Motivationmentioning
confidence: 99%
“…It has also been shown that the number of attempts required to sample a clinically significant tumor increases as needle delivery error of a biopsy system increases . Among other techniques, 3D to 2D registration is invaluable to reduce needle delivery error and has been investigated in a broad spectrum of interventions . Therefore, to compensate for misalignment error caused by prostate motion, two correction methods are feasible: (a) performing a single, intermittent user initiated registration correction before firing the biopsy needle, and (b) automatic, continuous correcting for any prostate motion throughout the biopsy procedure.…”
Section: Introductionmentioning
confidence: 99%