1995
DOI: 10.1016/0045-6535(95)00087-o
|View full text |Cite
|
Sign up to set email alerts
|

A review of environmental applications of bioluminescence measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
102
0
2

Year Published

2000
2000
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 171 publications
(104 citation statements)
references
References 126 publications
0
102
0
2
Order By: Relevance
“…Consequently, toxic agents that affect the metabolism or compromise bacterial viability cause a reduction in light output that is proportional to the toxicity of the sample. The results are expressed as effective concentration (EC 50 ) values at which there is a 50% decrease in light emission.…”
Section: The Microtox Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Consequently, toxic agents that affect the metabolism or compromise bacterial viability cause a reduction in light output that is proportional to the toxicity of the sample. The results are expressed as effective concentration (EC 50 ) values at which there is a 50% decrease in light emission.…”
Section: The Microtox Systemmentioning
confidence: 99%
“…Advances in molecular biology have made possible the cloning and expression of the luxAB genes in bacteria that are normally non-luminescent, transforming them into bioluminescent bacteria. The resulting transformations provide enormous applications (9,25) in industry (53), medicine (11,35), microbial ecology (6,29), and environmental fields (50).…”
Section: Introductionmentioning
confidence: 99%
“…The use of microorganisms as instruments for monitoring hydrocarbon-contaminated soil is not well established. However, microbial bioluminescence, microbial biomass/counts and soil respiration have been evaluated as potential tools for monitoring of hydrocarbons (Delistraty, 1984;Kandeler et al, 1994;Steinberg et al, 1995;Van Beelen and Doelman, 1997;Phillips et al, 2000).…”
Section: Microorganismsmentioning
confidence: 99%
“…In this process, the luciferase enzyme catalyses the transformation of luciferin to oxyluciferin where transition to the basic state due to the emission of light with an intensity proportional to the amount of ATP in the sample [2,11,12]. The intensity of light impulses that are formed in the luminescence reaction is measured at 562 nm and is expressed in Relative Light Units (RLU).…”
Section: Oxyluciferin + Amp + Products + Lightmentioning
confidence: 99%