IEEE/PES Transmission and Distribution Conference and Exhibition
DOI: 10.1109/tdc.2002.1177816
|View full text |Cite
|
Sign up to set email alerts
|

A recent trends in the implementation of Intranet based measurement and monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…On the whole, all the findings concern emaintenance implementations with various ICTs fulfilling different OSA-CBM layers. The complete integration of data, systems and processes emerges as an important requirement to fulfil for the [83] Web technology Customer service support Maintenance Ishihara et al [84] Web technology Web-based fault location system Power industry Marzi and John [85] Multi-agent system To support the operators of CNC machine tools in fault finding…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…On the whole, all the findings concern emaintenance implementations with various ICTs fulfilling different OSA-CBM layers. The complete integration of data, systems and processes emerges as an important requirement to fulfil for the [83] Web technology Customer service support Maintenance Ishihara et al [84] Web technology Web-based fault location system Power industry Marzi and John [85] Multi-agent system To support the operators of CNC machine tools in fault finding…”
Section: Discussionmentioning
confidence: 99%
“…Ishihara et al [84] describe the development of two kinds of hardware, the Network Computing Unit (NCU) and the Network Computing Terminal (NCT). They believe that these two technologies in conjunction with Internet and Intranet technologies can increase the efficiency in operation and maintenance through the protection and control of equipment.…”
Section: Other Findingsmentioning
confidence: 99%
“…The accuracy of time synchronization of the PMU is standardized at 1 µs by the IEEE (Institute of Electrical and Electronics Engineers) Power Engineering Society [13]. In Japan, a PMU confirming this standard has been developed [14][15][16], and has been used to observe and evaluate the oscillatory characteristics of Japan's 60-Hz systems [17,18]. In addition, we have developed an original PMU using a high-speed DSP (Digital Signal Processor) [19].…”
Section: System Specifications Required To Realize Proposed Methodsmentioning
confidence: 99%
“…Consumers always expect higher reliability and better quality of electric power supply, not only for outage but also for voltage sags which have a serious effect on industrial and commercial operations [1]. In order to improve the electric power supply quality, electrical power companies need to collect valuable information of electric-parameters (e.g.…”
Section: Introductionmentioning
confidence: 99%