2022
DOI: 10.1016/j.saa.2022.121163
|View full text |Cite
|
Sign up to set email alerts
|

A ratiometric ESIPT fluorescent probe for detection of anticancer-associated H2O2 level in vitro and in vivo

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 52 publications
0
6
0
Order By: Relevance
“…33) was prepared by using a benzylborate pinalol ester group as the H 2 O 2 recognition unit. 82,83 The pyridinium structure on the skeleton of HBQ could not only realize long-wavelength emission through the ICT mechanism but also facilitate mitochondrial targeting. HBQ-L showed sensitivity and selectivity for H 2 O 2 detection through a greento-red fluorescence response.…”
Section: Hydrogen Peroxide (H 2 O 2 ) Probes Associated With Cancermentioning
confidence: 99%
See 1 more Smart Citation
“…33) was prepared by using a benzylborate pinalol ester group as the H 2 O 2 recognition unit. 82,83 The pyridinium structure on the skeleton of HBQ could not only realize long-wavelength emission through the ICT mechanism but also facilitate mitochondrial targeting. HBQ-L showed sensitivity and selectivity for H 2 O 2 detection through a greento-red fluorescence response.…”
Section: Hydrogen Peroxide (H 2 O 2 ) Probes Associated With Cancermentioning
confidence: 99%
“…These results suggested that HBQ-L could be a promising tool to reveal the precise role of H 2 O 2 . 82…”
Section: Hydrogen Peroxide (H 2 O 2 ) Probes Associated With Cancermentioning
confidence: 99%
“…Various small molecule fluorescent probes have been designed for in vitro and in vivo detection of H 2 O 2 , including benzyl, boric acid ester, arylsulfonyl ester, etc. ( Chen et al, 2022 ; Gu et al, 2020 ; Guo et al, 2022 ). Previously reported H 2 O 2 fluorescence probes have some disadvantages such as single-wavelength, small Stokes shift, long response time, and low sensitivity ( Gao et al, 2017 ; Li et al, 2022b ).…”
Section: Introductionmentioning
confidence: 99%
“…Existing quantitative detection methods, such as titrimetry, electrochemistry, spectrophotometry and so on, are relatively mature techniques. 17–19 Fluorescent sensor analysis has the advantages of fast response, strong selectivity, adaptability and microscopic properties, and it has been widely used for detecting some analytes in biological and environmental systems. 20–23 At present, there are many reported sensors for H 2 O 2 which use aryl borate or phenyl boric acid reactions to generate phenol, phenol oxidation to give quinone, oxonium or diketone to give acid, carbon–carbon double bond breaking, and so on.…”
Section: Introductionmentioning
confidence: 99%