2012
DOI: 10.1080/15459624.2011.648569
|View full text |Cite
|
Sign up to set email alerts
|

A Radiometry Protocol for UVGI Fixtures Using a Moving-Mirror Type Gonioradiometer

Abstract: Ultraviolet germicidal irradiation (UVGI), 254 nm UV-C, is increasingly used as an infection control strategy to reduce the spread of airborne pathogens such as tuberculosis (TB), influenza viruses, and measles. With the appearance of multidrug-resistant TB and emerging infectious disease such as severe acute respiratory syndrome (SARS) and H1N1 influenza viruses, engineering controls using 254 nm UV-C lamps within specialized luminaires, herein designated UVGI fixtures, are being installed in high-risk settin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…The protocol used in this exercise follows that developed by Zhang et al . . It comprises 65 vertical angles, for 23 horizontal planes, a total of 1495 measuring points per luminaire.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The protocol used in this exercise follows that developed by Zhang et al . . It comprises 65 vertical angles, for 23 horizontal planes, a total of 1495 measuring points per luminaire.…”
Section: Methodsmentioning
confidence: 99%
“…Zhang et al . developed a protocol for the gonioradiometry of upper‐room UVGI luminaires based on standard photometry methods. Their experimental set‐up used a moving‐mirror Type‐C gonioradiometer.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Upper-air UVC fixtures can vary widely in their luminaire efficiency factors, which rates the performance of emitted UVC from a fixture. Zhang et al (2012) developed a protocol and performed gonioradiometric measurements (i.e., measuring both radiance and irradiance at concurrent angles) for upper-air UVGI fixtures, which is now being used to test total UVC fixture output (Leuschner and Salie 2013). These gonioradiometric measurements are reported in standard IES format compatible with computer-aided design (CAD) lighting software adapted for use with upper room UVC devices (Rudnick et al 2012;Vincent et al 2013).…”
Section: Safety Design Guidancementioning
confidence: 99%
“…This published guideline was the impetus for the development of a computer assisted design (CAD) program, discussed at the meeting, which was modified with the assistance of Acuity Lighting (Tim Sears) for use with UVGI . Its use requires full gonioradiometry of any fixture to be incorporated into a design . This is a powerful design tool, but so far only a handful of commercial fixtures have been fully characterized.…”
Section: High Humidity Settingsmentioning
confidence: 99%