2006
DOI: 10.1590/s1679-62252006000200018
|View full text |Cite
|
Sign up to set email alerts
|

A portable bio-amplifier for electric fish research: design and construction

Abstract: The weak electric organ discharges (EODs) of gymnotiform knife fishes can be readily amplified with a wideband amplifier connected to submerged electrodes. The output from such an amplifier can then be monitored with audio speakers or digitized for subsequent analysis. Commercially available devices are expensive and usually require mains electrical power. Here we provide design notes and instructions for the construction and calibration of a cheap, portable, battery-powered, AC-coupled wideband bio-amplifier.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2007
2007
2011
2011

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 2 publications
0
4
0
1
Order By: Relevance
“…Temperature was standardized to 27.0 ± 0.2 °C for at least 5 min before recording. Signals were amplified from tank‐end silver‐silver chloride or nickel‐chromium electrodes using an AC‐coupled amplifier (DC or 0.01 Hz–50 kHz; custom built following Wells & Crampton, 2006; CWE BMA 200; or Ametek SR‐5113) and digitized at 48–200 kHz (Sony TCD D3 or D7 DAT recorder; Edirol UA‐5; or National Instruments DAQ‐6052E). All EODs were saved as ASCII files for analysis in custom written MATLAB (The MathWorks, Natick, MA) or JAVA (Sun Microsystems, Inc., Santa Clara, CA) programs.…”
Section: Methodsmentioning
confidence: 99%
“…Temperature was standardized to 27.0 ± 0.2 °C for at least 5 min before recording. Signals were amplified from tank‐end silver‐silver chloride or nickel‐chromium electrodes using an AC‐coupled amplifier (DC or 0.01 Hz–50 kHz; custom built following Wells & Crampton, 2006; CWE BMA 200; or Ametek SR‐5113) and digitized at 48–200 kHz (Sony TCD D3 or D7 DAT recorder; Edirol UA‐5; or National Instruments DAQ‐6052E). All EODs were saved as ASCII files for analysis in custom written MATLAB (The MathWorks, Natick, MA) or JAVA (Sun Microsystems, Inc., Santa Clara, CA) programs.…”
Section: Methodsmentioning
confidence: 99%
“…Collections were made using standard ichthyological gear, including seine nets (5, 10 and 20 m, 5 mm between knots), dip nets, cast nets, traps, and hook and line. Electric fishes were located with the aid of a portable amplifier (Wells and Crampton 2006). A local fish-toxin called huaca (pronounced 'waka') was used in log jams of larger streams.…”
Section: Methodsmentioning
confidence: 99%
“…Individual fish were placed within a nylon-mesh sock. The electrodes were connected to a custom-built AC-coupled differential amplifier with a frequency response of +/-3 dB from 0.2 Hz-110 kHz (Wells & Crampton, 2006). EODs were digitized using an Edirol UA5 A-D converter at a sampling rate of 96 kHz and resolution of 24 bits.…”
Section: Methodsmentioning
confidence: 99%