2021
DOI: 10.1109/jmems.2021.3091651
|View full text |Cite
|
Sign up to set email alerts
|

A PMUT Integrated Microfluidic System for Fluid Density Sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…Additionally, note how the density plays an important role in the mass loading (β), achieving the highest value when FC-70 is used (lower frequency), even though this sample has 27 times lower viscosity than 100% of glycerol. To evaluate the sensitivity as demonstrated in 22 , the experimental data points were fitted (excluding 100% glycerol due to its high viscosity). The curve fitted using f media /f air is a linear function with a slope of −1.089e-4 [1/kg/m 3 ] and intercept of 0.55; see Fig.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Additionally, note how the density plays an important role in the mass loading (β), achieving the highest value when FC-70 is used (lower frequency), even though this sample has 27 times lower viscosity than 100% of glycerol. To evaluate the sensitivity as demonstrated in 22 , the experimental data points were fitted (excluding 100% glycerol due to its high viscosity). The curve fitted using f media /f air is a linear function with a slope of −1.089e-4 [1/kg/m 3 ] and intercept of 0.55; see Fig.…”
Section: Resultsmentioning
confidence: 99%
“…However, a pair of PMUTs are needed and, only low viscosity fluids can be measured. To overcome these drawbacks, in 22 , an array is presented where the individual element is a dual-electrode PMUT that facilitates detection of the density change at the expense of decreasing sensitivity (26.3 Hz/kg/m 3 , which is still in the range of the human blood density).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To address this drawback, a single-cell PMUT in a dual-electrode configuration has been developed and analyzed for density sensing [ 99 ]. Roy et al have further developed and investigated the sensing performance of a dual-electrode PMUT integrated with a microfluidic channel to identify the density variation in human blood [ 100 ]. The developed circular PMUT comprised PZT material of 500 nm thickness as the active piezoelectric layer along with gold-sensing and drive electrodes placed on a platinized SOI wafer, as illustrated in Figure 20 .…”
Section: Pmut Applicationsmentioning
confidence: 99%
“…The electromagnetic properties of light in conjunction with the penetrability of sound have made it possible to penetrate deeper and obtain information that is functional to the target thus probed. Pulsed LEDs and MUTs [24][25][26][27][28][29][30][31][32][33][34][35][36][37] have revolutionized the field further, thereby creating wearable photoacoustic devices. In this work, we have fabricated piezoelectric micromachined ultrasound transducers (PMUTs) using functional thin-film piezoelectric material and the nanofabrication tools and have demonstrated their use as a photoacoustic receiver.…”
Section: Introductionmentioning
confidence: 99%