A Parallel Miniature Cylindrical Ion Trap Array

Abstract: A small mass spectrometer array is described in which each element is a cylindrical ion trap (CIT). The array contains four CITs, each having an inner radius of 2.5 mm, arranged in parallel and operated using a single electronics system under common conditions for trapping and mass analysis. By using an array of identically sized traps, higher ion capacity can be achieved than with a single miniature CIT, but the advantage of lower power and voltage requirements associated with the smaller ion trap is maintain… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
66
0

Year Published

2000
2000
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 77 publications
(68 citation statements)
references
References 49 publications
2
66
0
Order By: Relevance
“…A small amount (20 mg) was placed in a stainless steel cup directly in front of the ion source, where it sublimed at a rate sufficient to raise the chamber pressure to between 5 x 10 -7 and 1 x 10 -6 Torr. 25 Figures 8 and 9 show mass spectra for the two compounds, obtained using devices equipped with 4mm and 2 mm pre-filter electrodes, respectively. In each case, the ion energy was V A = 2 eV and no pre-filter bias was used.…”
Section: Mass Rangementioning
confidence: 99%
See 1 more Smart Citation
“…A small amount (20 mg) was placed in a stainless steel cup directly in front of the ion source, where it sublimed at a rate sufficient to raise the chamber pressure to between 5 x 10 -7 and 1 x 10 -6 Torr. 25 Figures 8 and 9 show mass spectra for the two compounds, obtained using devices equipped with 4mm and 2 mm pre-filter electrodes, respectively. In each case, the ion energy was V A = 2 eV and no pre-filter bias was used.…”
Section: Mass Rangementioning
confidence: 99%
“…Particular attention has been devoted to cylindrical ion traps (CITs), since these may be easily constructed as planar arrays [22][23][24][25], and several portable systems containing CITs have been demonstrated [26][27][28][29]. More recently, microfabricated ion traps have been demonstrated in cylindrical [30][31][32][33], toroidal [34] and linear [35][36][37] arrangements.…”
Section: Introductionmentioning
confidence: 99%
“…For miniaturized traps, however, machining methods have been pushed to the limit, and simpler electrode geometries such as planar and cylindrical are required. For this reason, most miniaturized and microfabricated ion traps have utilized the cylindrical trap design [12,[16][17][18][19][20].The need for a portable mass spectrometer has largely driven efforts to produce miniaturized ion traps [21]. Although the mass analyzer is just one of several components of a complete mass spectrometer system, miniaturization of the mass analyzer can often reduce the size and weight of other components.…”
mentioning
confidence: 99%
“…For miniaturized traps, however, machining methods have been pushed to the limit, and simpler electrode geometries such as planar and cylindrical are required. For this reason, most miniaturized and microfabricated ion traps have utilized the cylindrical trap design [12,[16][17][18][19][20].…”
mentioning
confidence: 99%
“…The dimensions of some of these mass analyzers are about a millimeter or smaller. As mass analyzer dimensions decrease, vacuum requirements also typically decrease due to the shorter ion path and correspondingly shorter tolerable mean free path [11,18]. Similarly, power requirements typically decrease as the sizes of capacitive and inductive components are reduced, or as the required voltage needed for a given field strength decreases.…”
mentioning
confidence: 99%