A Nutation Nuclear-Magnetic Teslameter for Measuring Weak Magnetic Fields

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 56 publications
(16 citation statements)
references
References 1 publication
0
15
0
1
Order By: Relevance
“…[4][5][6]8,9 The value of the induction B in this device is determined by the gyromagnetic ratio of the proton γ p and frequency f n of the nuclear resonance. 4,[8][9][10][11][12] The contact between the induction and to previously submitted values is determined by the relation…”
Section: Formulation Of the Problemmentioning
confidence: 99%
See 1 more Smart Citation
“…[4][5][6]8,9 The value of the induction B in this device is determined by the gyromagnetic ratio of the proton γ p and frequency f n of the nuclear resonance. 4,[8][9][10][11][12] The contact between the induction and to previously submitted values is determined by the relation…”
Section: Formulation Of the Problemmentioning
confidence: 99%
“…[4][5][6][8][9][10][11][12] This change of orientation M p after of liquid passage the connecting sections pipeline 6 and the flow switch 4 is fixed of NMR signal registration coil 10. The coil 10 is a part the newly developed generator circuit vibrations weak (autodyne) which located in the registration device 11.…”
Section: Formulation Of the Problemmentioning
confidence: 99%
“…In cases in which at least one of conditions (3) and/or the condition for inhomogeneity of constant magnetic field H 0 is not satisfied, it is impossible to determine the shape of the nutation line (with satel lites) in RF modulated magnetic field H 0 for improve ment of the accuracy of physical measurements in NMR magnetometers, flowmeters, and relaxometers.…”
Section: Equations Of Motion Of the Nuclear Magnetization Vector Of Amentioning
confidence: 99%
“…
At present, flowmeters based on nuclear magnetic resonance (NMR) are finding numerous applications in atomic power engineering (monitoring of cooling systems), in technologies employing aggressive chem ical media (e.g., acids and alkali) and biological solu tions (under sterile conditions), and in the petro chemical industry [1][2][3][4]. An important advantage of NMR flowmeters in comparison to other types con sists in the absence of a contact between the measuring system and flowing liquid.
…”
mentioning
confidence: 99%
“…When operating nuclear power plants (NPPs) of various capacities, several tasks arise. One of them is the creation of control and monitoring systems that ensure the stable operation of equipment operating in continuous mode at nuclear power plants [25][26][27][28][29][30][31][32]. And to provide reliable remote control of various systems and units of the station, for example, when the station is decommissioned, or in the "conservation" mode of a nuclear reactor [6,9,[23][24][25][26].…”
Section: Introductionmentioning