2007
DOI: 10.1016/j.sab.2007.10.005
|View full text |Cite
|
Sign up to set email alerts
|

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
112
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 210 publications
(118 citation statements)
references
References 28 publications
4
112
0
Order By: Relevance
“…A second -less common -application is laser ablation mass spectrometry (LAMS) [27,28], where the ions formed during the ablation process are directly transferred into a mass spectrometer for analysis. Both former approaches are somewhat limited for quantitative analysis of samples, where matrix-matched calibration standards are not readily available [29][30][31]. Matrix-assisted laser desorption and ionization (MALDI) [32] may be considered an approach similar to LAMS.…”
Section: Fundamental Aspects Of Laser Ablationmentioning
confidence: 99%
“…A second -less common -application is laser ablation mass spectrometry (LAMS) [27,28], where the ions formed during the ablation process are directly transferred into a mass spectrometer for analysis. Both former approaches are somewhat limited for quantitative analysis of samples, where matrix-matched calibration standards are not readily available [29][30][31]. Matrix-assisted laser desorption and ionization (MALDI) [32] may be considered an approach similar to LAMS.…”
Section: Fundamental Aspects Of Laser Ablationmentioning
confidence: 99%
“…CF-LIBS relies on determining the temperature of the plasma from a Saha-Boltzmann plot [6] drawn for each emitting species in the plasma plume. In these studies, seven atomic and three ionic lines of beryllium and 27 atomic and 12 ionic lines of tungsten within the wavelength range 253-490 nm were chosen for the analyses.…”
Section: Quantitative Studies By Calibration-free Libsmentioning
confidence: 99%
“…LIBS spectra can be used in two distinct ways -elemental analysis 6,7 and material classification/identification 3,8 . While the elemental analysis utilises calibration 9 , calibration -free 10,11 or multivariate methods 12 , classification/identification relies predominantly on the multivariate methods 3,12 . LIBS has added a new paradigm in various fields like space 13 , archaeology 14 , biology 15 , isomer identification 16 biomedical 17,18 , industrial 19 , defense 2,20 , food processing 21 , nuclear waste 22 and forensics 23,24 .…”
Section: Introductionmentioning
confidence: 99%