Abstract: This work demonstrates the potential of inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) in trace element analysis. Aiming Hg determination in water, sample preservation requires chloride addition, which presents formation of polyatomic interfering ions as a drawback for the determination of other analytes (e.g. As and V). Thus, the effect of chloride on As, Cr, V and Hg determination and the feasibility of using ICP-MS/MS to circumvent the interference were evaluated. A standard reference mater… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(18 citation statements)
references
References 20 publications
(44 reference statements)
0
18
0
Order By: Relevance
“…It presents an octopole reaction system (ORS 3 ) located in-between two quadrupole analyzers and allows the operation of the ICP-MS instrument in MS/MS mode. This configuration improves the control of collision and reaction processes inside the ORS 3 due to the pre-selected mass/charge ratio, and it has been successfully applied in order to determine several elements in different types of sample (Balcaen et al 2013;Amais et al 2014Amais et al , 2015Amaral et al 2015;Virgilio et al 2015).…”
Section: Introductionmentioning
confidence: 97%
“…It presents an octopole reaction system (ORS 3 ) located in-between two quadrupole analyzers and allows the operation of the ICP-MS instrument in MS/MS mode. This configuration improves the control of collision and reaction processes inside the ORS 3 due to the pre-selected mass/charge ratio, and it has been successfully applied in order to determine several elements in different types of sample (Balcaen et al 2013;Amais et al 2014Amais et al , 2015Amaral et al 2015;Virgilio et al 2015).…”
Section: Introductionmentioning
confidence: 97%
“…The productivities of the gaseous CH 3 Hg + ions by CH 3 I in the dark reactor in our work are close to the productivities of the aqueous CH 3 Hg + ions by UV irradiation reported by Yin et al 16 In addition, our work also demonstrates that this methylation reaction can occur even at extremely low gas pressures, for the ORS 3 in the ICP-MS/MS is a near-vacuum environment. 27,[30][31][32][33] In this study, we use an ICP-MS/MS instrument as the tool to study inorganic mercury methylation, which expands the application range of ICP-MS/MS for elements determination. Fig.…”
Section: Further Discussionmentioning
confidence: 99%
“…S1 †). 31 Four L1 metabolites can be resolved using different column dimensions without the oxidation step during sample preparation (Fig. Weapons-grade Lewisite contained on average $1% wt gem-L1; however, in some munitions the geminal isomer was not detectable.…”
Section: Methods Selectivitymentioning
confidence: 99%