2022
DOI: 10.1016/j.electacta.2022.140855
|View full text |Cite
|
Sign up to set email alerts
|

A novel strategy for the detection of pyruvate in fermentation processes based on well-distributed enzyme-inorganic hybrid nanoflowers on thiol graphene modified gold electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 50 publications
0
10
0
Order By: Relevance
“…Upon optimization, the developed H 2 O 2 and pyruvate biosensor demonstrated a LOD of 0.06 and 0.3 mM (S/N = 3) in the linear range of 0.1-8.2 and 1-8 mM, respectively, as well as good accuracy and sensitivity. 50 In a study conducted by Baek et al, GOx-HRP hNFs-Au NP-decorated GO nanofibers (NFs) was fabricated for the electrochemical glucose biosensor. In this work, firstly, GO NFs were synthesized on the gold chip by the electrospinning method.…”
Section: Electrochemical Detection Based On Hnfsmentioning
confidence: 99%
See 1 more Smart Citation
“…Upon optimization, the developed H 2 O 2 and pyruvate biosensor demonstrated a LOD of 0.06 and 0.3 mM (S/N = 3) in the linear range of 0.1-8.2 and 1-8 mM, respectively, as well as good accuracy and sensitivity. 50 In a study conducted by Baek et al, GOx-HRP hNFs-Au NP-decorated GO nanofibers (NFs) was fabricated for the electrochemical glucose biosensor. In this work, firstly, GO NFs were synthesized on the gold chip by the electrospinning method.…”
Section: Electrochemical Detection Based On Hnfsmentioning
confidence: 99%
“…HRP‐hNFs/tG/Au electrode showed enhanced activity and conductivity owing to high catalytic activity and excellent electrochemical performance of the hNFs. Upon optimization, the developed H 2 O 2 and pyruvate biosensor demonstrated a LOD of 0.06 and 0.3 mM (S/N = 3) in the linear range of 0.1–8.2 and 1–8 mM, respectively, as well as good accuracy and sensitivity 50 …”
Section: Application Of Hnfsmentioning
confidence: 99%
“…According to the data in Table 3, the parameters of the Cu 3 (PO 4 ) 2 unit cell (triclinic crystal system) were calculated as follows: a = 0.4857 nm, b = 0.5292 nm, c = 0.6159 nm, α = 72.48°, β = 87.02°, γ = 68.46° and V = 0.1401 nm 3 . Let us compare these values with the results of Shoemaker et al [33]: a = 0.4853 nm, b = 0.5285 nm, c = 0.6182 nm, α = 72.35°, β = 86.99°, γ = 68.54° and V = 0.1403 nm 3 . As could be seen, the minimum difference between the parameters of this work and those published in the literature [33] is 0.03%, and the maximum is 0.37%.…”
Section: Physicochemical Analysis Of Cu 3 (Po 4 ) 2 •3h 2 Omentioning
confidence: 99%
“…In the past few years, copper (II) orthophosphate trihydrate Cu 3 (PO 4 ) 2 •3H 2 O has gained a significant increase of the scientific interest. Thus, a number of promising composites have been obtained with the participation of this compound: a colorimetric platform for glucose detection [1], a colorimetric biosensor for epinephrine identification [2], a nanomaterial for pyruvate specification in fermentation processes [3], a catalyst for olive oil hydrolysis [4], a surfactant [5], an enzyme immobilizer [6] and a nanocatalyst for the hydrolysis of allergenic cow᾽s milk proteins [7].…”
Section: Introductionmentioning
confidence: 99%
“…In spite of the long history of S. cerevisiae as an industrial microorganism, the problems related to pyruvate transport, distribution, and fluctuation in different subcellular compartmentalizations are still not completely understood. , Standard methods to measure pyruvate have been reported, such as amperometric, spectrophotometric, and high-performance liquid chromatography (HPLC) techniques. , However, these methods only allow the detection of extracellular pyruvate and cannot reflect the physiological state of microbial cells in real time . Obtaining spatiotemporal information about metabolites through these traditional monitoring methods after cell lysis is time-consuming and incompatible with the study of spatiotemporal dynamics in single and intact cells …”
Section: Introductionmentioning
confidence: 99%