2019
DOI: 10.1109/tpel.2018.2880461
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Sensorless Photovoltaic Power Reserve Control With Simple Real-Time MPP Estimation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
37
0
5

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(42 citation statements)
references
References 46 publications
0
37
0
5
Order By: Relevance
“…In [22] and [23], a small PV module was added to measure the open-circuit voltage (or short-circuit current), which requires additional hardware and increases the cost and complexity. In [24], the short-circuit current was estimated by the sampled current and voltage, but it required PV array parameters and solved the complex Lambert-W function to calculate MAP. Furthermore, compromised by the inevitable deviations of actual PV array parameters from data sheet values, the accuracy of MAP estimates will be affected.…”
Section: Introductionmentioning
confidence: 99%
“…In [22] and [23], a small PV module was added to measure the open-circuit voltage (or short-circuit current), which requires additional hardware and increases the cost and complexity. In [24], the short-circuit current was estimated by the sampled current and voltage, but it required PV array parameters and solved the complex Lambert-W function to calculate MAP. Furthermore, compromised by the inevitable deviations of actual PV array parameters from data sheet values, the accuracy of MAP estimates will be affected.…”
Section: Introductionmentioning
confidence: 99%
“…However, unlike conventional generators, PV systems have no natural inertia and must reserve some of the available power to participate in the system frequency response [8][9][10]. In principle, there is two methods for implementing the power reserve: (i) installation of an energy storage device, such as a battery or a supercapacitor, which has the disadvantage of increasing the system maintenance costs and complexity [5,8,[11][12][13][14][15]; (ii) operation of PV systems at a suboptimal power point to reserve partial frequency regulation power, which is simple and costeffective [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31]. This study is focused on the latter method.…”
Section: Introductionmentioning
confidence: 99%
“…In [24], an additional small PV module is used to measure the short‐circuit current, and an off‐line fitting function of the short‐circuit current and the maximum power is used to estimate MAP. In [25], the PV operates in the constant current region. The measurement PV array current is used to estimate the short‐circuit current to further estimate the maximum power point (MPP) current and the MPP power.…”
Section: Introductionmentioning
confidence: 99%
“…Entretanto, a operação descarregada também acarreta na redução da receita proveniente da venda de energia (Dreidy, Mokhlis e Mekhilef, 2017). Todavia, do ponto de vista do operador do sistema elétrico, a operação descarregada das unidades renováveis é uma alternativa mais barata para a manutenção da frequência do sistema quando comparada à instalação de banco de baterias ou à operação das unidades síncronas convencionais em níveis mínimos de potência (Liu et al, 2018;Li et al, 2019). Ademais, a perda de receita atrelada à redução da geração pode ser compensada pela renda obtida na prestação de serviços ancilares (Rajan e Fernandez, 2019).…”
Section: Introductionunclassified