2016
DOI: 10.1016/j.snb.2016.02.052
|View full text |Cite
|
Sign up to set email alerts
|

A novel sensor for a food dye erythrosine at glucose modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
27
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1
1

Relationship

3
6

Authors

Journals

citations
Cited by 80 publications
(27 citation statements)
references
References 33 publications
0
27
0
Order By: Relevance
“…An overview of the improvement in electroanalytical chemistry demonstrates that solid metal electrodes represent the most rapidly rising class of electrodes [Shetti et al 2009;Jorge et al 2010;Wudarska et al 2013]. Among all those electrodes, the utilization of glassy carbon electrode for the electrochemical measurements has increased in recent years as they provide good sensitivity, negligible porosity, and superior mechanical rigidity [Nayak and Shetti 2016]. Oxidation and reduction property of drugs can give insight into its metabolic providence or their in vivo redox process or pharmaceutical activity [Kumar et al 2008;Diculescu et al 2006].…”
Section: Introductionmentioning
confidence: 99%
“…An overview of the improvement in electroanalytical chemistry demonstrates that solid metal electrodes represent the most rapidly rising class of electrodes [Shetti et al 2009;Jorge et al 2010;Wudarska et al 2013]. Among all those electrodes, the utilization of glassy carbon electrode for the electrochemical measurements has increased in recent years as they provide good sensitivity, negligible porosity, and superior mechanical rigidity [Nayak and Shetti 2016]. Oxidation and reduction property of drugs can give insight into its metabolic providence or their in vivo redox process or pharmaceutical activity [Kumar et al 2008;Diculescu et al 2006].…”
Section: Introductionmentioning
confidence: 99%
“…[20][21][22][23][24] The fabrication of the working electrode with nanoparticles enhances peak current, sensitivity, reproducibility. 25,26 In current science and technology, one of the crucial uniqueness is to survey and to discover the new efficient materials as electrode surface modifiers.…”
mentioning
confidence: 99%
“…For DPV studies, the following parameters were maintained: Sweep rate-20 mV/s, pulse amplitude-50 mV, pulse width-60 ms, pulse period-500 ms for analytical applications. All experiments were carried out at 25±1°C [32][33][34][35].…”
Section: Analytical Proceduresmentioning
confidence: 99%