2015
DOI: 10.1016/j.aca.2015.08.007
|View full text |Cite
|
Sign up to set email alerts
|

A novel paper-based device coupled with a silver nanoparticle-modified boron-doped diamond electrode for cholesterol detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
33
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 76 publications
(41 citation statements)
references
References 41 publications
(28 reference statements)
1
33
0
Order By: Relevance
“…The H 2 O 2 generated by the enzymatic reaction in the presence of cholesterol was reduced at the NPs modified working electrode, generating a current signal that was measured by amperometry. The biosensor exhibited a high selectivity for cholesterol detection and an excellent performance in terms of detection limits (comparable to other previously reported biosensors) and for real sample analysis (bovine serum) [41]. …”
Section: Paper-based Electrochemical Biosensorssupporting
confidence: 68%
See 1 more Smart Citation
“…The H 2 O 2 generated by the enzymatic reaction in the presence of cholesterol was reduced at the NPs modified working electrode, generating a current signal that was measured by amperometry. The biosensor exhibited a high selectivity for cholesterol detection and an excellent performance in terms of detection limits (comparable to other previously reported biosensors) and for real sample analysis (bovine serum) [41]. …”
Section: Paper-based Electrochemical Biosensorssupporting
confidence: 68%
“…In a different approach, Nantaphol et al developed a cholesterol biosensor by coupling a paper analytical device with a commercial boron-doped diamond electrode [41]. The paper section had carbon counter and Ag/AgCl reference electrodes screen-printed on its hydrophilic areas.…”
Section: Paper-based Electrochemical Biosensorsmentioning
confidence: 99%
“…Considering the manual processing for manufacturing ePADs, the achieved RSD is acceptable and demonstrates that the proposed approach exhibits high reproducibility. It is important to highlight that the RSD values achieved in this current study are lower than most reports associated with ePADs created with graphite pencil . The low RSD values can be associated with the use of a polyester mold for defining the electrode area, which ensures better reproducibility.…”
Section: Resultsmentioning
confidence: 61%
“…While the performance of the ePADs is below other references , two advantages need to be highlighted. First, ePADs were prepared and used without any modification with nanomaterials or charge transfer mediators.…”
Section: Resultsmentioning
confidence: 99%
“…However, the results obtained with the developed NiO modified graphite based µPAD are superior to those reported in terms of both linear range and detection limit. Nantaphol et al have developed Ag nanoparticle modified boron doped diamond electrode and integrated it with the paper based microchannels . The fabrication of electrode and channels separately complicates the device design and the use of Ag and diamond electrodes increases the relative cost of the sensor.…”
Section: Resultsmentioning
confidence: 78%