Abstract: A three-phase voltage source PWM rectifier(VSR) has some shortcomings that can lead to resonance, resulting in system instability problems. A novel multi-loop control strategy and a design of the control structure in synchronous coordinate system for LCL-VSR is proposed in this paper to solve the problem. The strategy belongs to active damping control, which introduces the filter capacitor current-loop feedback control on the basis of the traditional double-loop control system. The strategy increases the syste… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 5 publications
(1 reference statement)
0
5
0
Order By: Relevance
“…The current ripple of 1 i also should be suppressed in order to reduce power lose and temperature rise of the converter-side inductor [5]. Substituting 0 0.5 α = into (6), (7), one can get (8), (9). According to (8) and ( 9), the influence of change of α around 0 0.5 α =…”
Section: A Selection Of Total Inductancementioning
confidence: 99%
See 1 more Smart Citation
“…The current ripple of 1 i also should be suppressed in order to reduce power lose and temperature rise of the converter-side inductor [5]. Substituting 0 0.5 α = into (6), (7), one can get (8), (9). According to (8) and ( 9), the influence of change of α around 0 0.5 α =…”
Section: A Selection Of Total Inductancementioning
confidence: 99%
“…Active methods suppress resonance through the control strategy which cause no extra power lose. In this paper, an active method based on the feedback of capacitor current [7] is put into use. ( ) 1 ( ) ( )…”
Section: Active Damping For Lcl-filtermentioning
confidence: 99%
“…The promising solution is the three cascade control to get all three state variable information. To intensify the stability of the system, H. Zhang et al [16] have incorporated an additional capacitor current-loop feedback along with a traditional double-loop control system. However, the shortcoming of this technique is the need for more sensor counts for getting all three measuring points.…”
Section: Introductionmentioning
confidence: 99%
“…Taken the three-phase three-wire APF as an example, this paper firstly introduces the design of the DC voltage controller [10 -13]. Then the relationship between DC voltage and the power loss as well as the compensation performance of APF is analysed [14,15]. Finally, a new control scheme with a droop controller is developed to regulate DC voltage [16].…”
Section: Introductionmentioning