A novel method for inward fluid displacement in centrifugal microdevices for highly integrated nucleic acid processing with long-term reagent storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 48 publications
0
4
0
Order By: Relevance
“…Two separate instances where this has been effectively demonstrated on a platform include Dignan et al (Fig. 10C) 247 and Aeinehvand et al (Fig. 10D).…”
Section: Structural Applicationsmentioning
confidence: 97%
See 1 more Smart Citation
“…Two separate instances where this has been effectively demonstrated on a platform include Dignan et al (Fig. 10C) 247 and Aeinehvand et al (Fig. 10D).…”
Section: Structural Applicationsmentioning
confidence: 97%
“…[243][244][245] This can be particularly useful during heating steps which cause fluidic expansion and risk liquid escape. 22,246,247 They may also act as physical barriers capable of avoiding analyst exposure to potentially toxic compounds or contamination of nucleic acid amplification tests (NAATs). 248 Intriguingly, they may also be efficiently leveraged to help generate pneumatic pressure on-disc to drive fluid displacement.…”
Section: Structural Applicationsmentioning
confidence: 99%
“…The on-disc sample handling is implemented by a centrifugal force and the various valves are involved in sample/solution transfer between different sample preparation processes [95,96]. These disc devices are most frequently used for protein [38,97], genes [65,98], bacteria [64,99], and cell [100,101] analysis containing multiple processes. Some of these discs are employed as user-friendly sample preparation equipment for the off-line detection, such as LC-MS/MS [38,97].…”
Section: Lab-on-a-chip Sample Preparation Techniquesmentioning
confidence: 99%
“…In a notable exception, using immiscible liquid check valves with pumping structures has permitted efficient pumping at more sedate acceleration/deceleration profiles [24]. Chemical pumping, where gas is released from a chemical reaction and displaces a liquid inwards, has also been demonstrated to have a good effect [24][25][26].…”
Section: Introductionmentioning
confidence: 99%